EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Mixed Reality Surgical Navigation System; Positional Accuracy Based on Food and Drug Administration Standard

Christopher T Morley, David M Arreola iD, Long Qian, Amy L Lynn, Zachary P Veigulis, Thomas F Osborne iD

Surgical Innovation · 2024-02 · 31 (1) · 48-57

DOI: 10.1177/15533506231217620 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Surgical Innovation, online erschienen am 29.11.2023. Verfasst von Christopher T Morley und 5 weiteren Autor:innen. Beteiligte Einrichtung: Medivis, Inc., New York, NY, USA. Hauptthemen laut MEDLINE: Augmented Reality, Surgery, Computer-Assisted. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Computer assisted surgical navigation systems are designed to improve outcomes by providing clinicians with procedural guidance information. The use of new technologies, such as mixed reality, offers the potential for more intuitive, efficient, and accurate procedural guidance. The goal of this study is to assess the positional accuracy and consistency of a clinical mixed reality system that utilizes commercially available wireless head-mounted displays (HMDs), custom software, and localization instruments.

Methods

Independent teams using the second-generation Microsoft HoloLens © hardware, Medivis SurgicalAR © software, and localization instruments, tested the accuracy of the combined system at different institutions, times, and locations. The ASTM F2554-18 consensus standard for computer-assisted surgical systems, as recognized by the U.S. FDA, was utilized to measure the performance. 288 tests were performed.

Results

The system demonstrated consistent results, with an average accuracy performance that was better than one millimeter (.75 ± SD .37 mm).

Conclusion

Independently acquired positional tracking accuracies exceed conventional in-market surgical navigation tracking systems and FDA standards. Importantly, the performance was achieved at two different institutions, using an international testing standard, and with a system that included a commercially available off-the-shelf wireless head mounted display and software.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Augmented RealitySurgery, Computer-AssistedUnited StatesSurgical Navigation SystemsUnited States Food and Drug AdministrationSoftware

Stichwörter der Autor:innen

Augmented realityHoloLenscomputer-assisted surgerymixed realitysurgical navigation

Autor:innen und Institutionen

  • Medivis, Inc., New York, NY, USA.
  • US Department of Veterans Affairs, Palo Alto Healthcare System, Palo Alto, CA, USA.
  • Department of Business Analytics, Tippie College of Business, University of Iowa, Iowa, IA, USA.
  • Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA.

ORCID-Profile: David M Arreola, Thomas F Osborne

Zitieren

APA

Morley, C. T., Arreola, D. M., Qian, L., Lynn, A. L., Veigulis, Z. P., & Osborne, T. F. (2024). Mixed Reality Surgical Navigation System; Positional Accuracy Based on Food and Drug Administration Standard. Surgical Innovation, 31(1), 48-57. https://doi.org/10.1177/15533506231217620

Vancouver

Morley CT, Arreola DM, Qian L, Lynn AL, Veigulis ZP, Osborne TF. Mixed Reality Surgical Navigation System; Positional Accuracy Based on Food and Drug Administration Standard. Surgical Innovation. 2024;31(1):48-57. doi:10.1177/15533506231217620

BibTeX
@article{Morley2024,
  author = {Morley, Christopher T and Arreola, David M and Qian, Long and Lynn, Amy L and Veigulis, Zachary P and Osborne, Thomas F},
  title = {Mixed Reality Surgical Navigation System; Positional Accuracy Based on Food and Drug Administration Standard},
  journal = {Surgical Innovation},
  year = {2024},
  volume = {31},
  number = {1},
  pages = {48--57},
  doi = {10.1177/15533506231217620}
}
Kostenlos starten →