EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Quantify the Effect of Air Gap Errors on Skin Dose for Breast Cancer Radiotherapy

Chunbo Tang iD, Jun Yuan, Hailiang Guo, Zhongyang Dai, Biaoshui Liu, Haiyan Xi, Ji He, Shanzhou Niu

Technology in Cancer Research & Treatment · 2024

DOI: 10.1177/15330338241258566 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technology in Cancer Research & Treatment, 2024. Verfasst von Chunbo Tang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, First Affiliated Hospital of Gannan Medical University, Ganzhou, China. Hauptthemen laut MEDLINE: Breast Neoplasms, Radiotherapy Planning, Computer-Assisted, Skin, Radiotherapy Dosage. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Jiangxi Double Thousand Plan, National Natural Science Foundation of China, Science and Technology Program of Jiangxi Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Determining the impact of air gap errors on the skin dose in postoperative breast cancer radiotherapy under dynamic intensity-modulated radiation therapy (IMRT) techniques.

Methods

This was a retrospective study that involved 55 patients who underwent postoperative radiotherapy following modified radical mastectomy. All plans employed tangential IMRT, with a prescription dose of 50 Gy, and bolus added solely to the chest wall. Simulated air gap depth errors of 2 mm, 3 mm, and 5 mm were introduced at depression or inframammary fold areas on the skin, resulting in the creation of air gaps named Air2, Air3, and Air5. Utilizing a multivariable GEE, the average dose ( D mean ) of the local skin was determined to evaluate its relationship with air gap volume and the lateral beam's average angle (AALB). Additionally, an analysis was conducted on the impact of gaps on local skin.

Results

When simulating an air gap depth error of 2 mm, the average D mean in plan2 increased by 0.46 Gy compared to the initial plan (planO) ( p < .001). For the 3-mm air gap, the average D mean of plan3 was 0.51 Gy higher than that of planO ( p < .001). When simulating the air gap as 5 mm, the average D mean of plan5 significantly increased by 0.59 Gy compared to planO ( p < .001). The TCP results showed a similar trend to those of D mean . As the depth of air gap error increases, NTCP values also gradually rise. The linear regression of the multivariable GEE equation indicates that the volume of air gaps and the AALB are strong predictors of D mean .

Conclusion

With small irregular air gap errors simulated in 55 patients, the values of skin's D mean , TCP, and NTCP increased. A multivariable linear GEE regression model may effectively explain the impact of air gap volume and AALB on the local skin.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breast NeoplasmsRadiotherapy Planning, Computer-AssistedSkinRadiotherapy DosageRadiotherapy, Intensity-ModulatedHumansFemaleRetrospective StudiesMiddle Aged

Stichwörter der Autor:innen

air gap errorslocal skin dosenormal tissue complication probabilitytumor control probability

Autor:innen und Institutionen

  • Department of Radiation Oncology, First Affiliated Hospital of Gannan Medical University, Ganzhou, China.
  • Jiangxi Clinical Research Center for Cancer, Ganzhou, China.
  • Department of Radiation Oncology, Sun Yat-sen University Cancer Center, Guangzhou, China.
  • Department of Radiation Oncology, Nanchang People's Hospital, Nanchang, China.
  • School of Biomedical Engineering, Fourth Affiliated Hospital of Guangzhou, Guangzhou Medical University, Guangzhou, China.
  • School of Mathematics and Computer Science / Ganzhou Key Laboratory of Computational Imaging, Gannan Normal University, Ganzhou, China.

ORCID-Profile: Chunbo Tang

Förderung

  • Jiangxi Double Thousand Plan
  • National Natural Science Foundation of China
  • Science and Technology Program of Jiangxi Province

Zitieren

APA

Tang, C., Yuan, J., Guo, H., Dai, Z., Liu, B., Xi, H., He, J., & Niu, S. (2024). Quantify the Effect of Air Gap Errors on Skin Dose for Breast Cancer Radiotherapy. Technology in Cancer Research & Treatment. https://doi.org/10.1177/15330338241258566

Vancouver

Tang C, Yuan J, Guo H, Dai Z, Liu B, Xi H, et al. Quantify the Effect of Air Gap Errors on Skin Dose for Breast Cancer Radiotherapy. Technology in Cancer Research & Treatment. 2024. doi:10.1177/15330338241258566

BibTeX
@article{Tang2024,
  author = {Tang, Chunbo and Yuan, Jun and Guo, Hailiang and Dai, Zhongyang and Liu, Biaoshui and Xi, Haiyan and He, Ji and Niu, Shanzhou},
  title = {Quantify the Effect of Air Gap Errors on Skin Dose for Breast Cancer Radiotherapy},
  journal = {Technology in Cancer Research & Treatment},
  year = {2024},
  doi = {10.1177/15330338241258566}
}
Kostenlos starten →