EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A pilot evaluation of CAD-based 3D body-scan anthropometry for electrode-referenced measurements in smart clothing

Sojung Lee, Siyeon Kim, Daeyoung Lim, Wonyoung Jeong

Journal of Industrial Textiles · 2026-03 · 56

DOI: 10.1177/15280837261431379 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Industrial Textiles, online erschienen am 03.03.2026. Verfasst von Sojung Lee und 3 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Korea Institute of Industrial Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This pilot study evaluates the reliability and systematic bias of CAD-based 3D body-scan anthropometry (3DM) for electrode-referenced measurements in smart clothing applications. Anthropometric data from 24 male participants were obtained using both manual measurement (MM) and CAD-based analysis of 3D scan data across five dimensions relevant to EMG-enabled garments. Reliability was assessed using intraclass correlation coefficients (ICC), and agreement was examined through Bland–Altman analysis. The results demonstrated excellent reliability for all measurements (ICC > 0.9), indicating strong consistency between MM and 3DM. However, systematic biases were observed: 3DM underestimated biacromion length, primarily due to standardized scanning posture, and overestimated waist circumference, reflecting the absence of soft-tissue compression in non-contact scanning. In contrast, short surface paths between anatomical landmarks and electrode sites exhibited minimal bias and high agreement. These findings suggest that while CAD-based 3D scan anthropometry provides stable and reproducible electrode-referenced measurements, certain dimensions require careful interpretation due to posture- and curvature-related effects. This methodological evaluation establishes a foundation for the informed use of 3D scan–derived anthropometric data in future smart clothing and wearable system development.

Förderung

  • Korea Institute of Industrial Technology

Zitieren

APA

Lee, S., Kim, S., Lim, D., & Jeong, W. (2026). A pilot evaluation of CAD-based 3D body-scan anthropometry for electrode-referenced measurements in smart clothing. Journal of Industrial Textiles, 56. https://doi.org/10.1177/15280837261431379

Vancouver

Lee S, Kim S, Lim D, Jeong W. A pilot evaluation of CAD-based 3D body-scan anthropometry for electrode-referenced measurements in smart clothing. Journal of Industrial Textiles. 2026;56. doi:10.1177/15280837261431379

BibTeX
@article{Lee2026,
  author = {Lee, Sojung and Kim, Siyeon and Lim, Daeyoung and Jeong, Wonyoung},
  title = {A pilot evaluation of CAD-based 3D body-scan anthropometry for electrode-referenced measurements in smart clothing},
  journal = {Journal of Industrial Textiles},
  year = {2026},
  volume = {56},
  doi = {10.1177/15280837261431379}
}
Kostenlos starten →