EUVIMEDEUVIMED entdecken
Multizentrische StudieBeobachtungsstudie

Fenestrated Endovascular Aortic Repair of Complex Aneurysm Using the Anaconda Fenestrated Device: 1-Year Results From the French Multicenter Registry

Alexandre Oliny iD, Marc-Antoine Vasseur, Nicolas Frisch, Yves Alimi, Virgile Omnes, Eric Ducasse, Jean-Noël Albertini, Antoine Millon

Journal of Endovascular Therapy · 2026

DOI: 10.1177/15266028241284034 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Endovascular Therapy, 2026. Verfasst von Alexandre Oliny und 7 weiteren Autor:innen. Beteiligte Einrichtung: Vascular Surgery Department, Hopital Louis Pradel, Hospices Civils de Lyon, Bron, France. Hauptthemen laut MEDLINE: Blood Vessel Prosthesis, Endovascular Procedures, Blood Vessel Prosthesis Implantation, Stents. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aims to assess the safety and efficacy of the fenestrated Anaconda device for the treatment of complex aortic aneurysms over 1 year in daily clinical practice. Materials and Methods: All patients who received the graft between October 2019 and October 2020 were prospectively enrolled in an observational, multicenter national registry. The primary endpoint was the aneurysm-related 1-year mortality rate. Secondary endpoints included all-cause mortality, technical success, device-related adverse events (AEs) and major complications, secondary reinterventions, endoleaks, target vessel (TV) outcomes, and a center-volume analysis comparing mortality and secondary reintervention rate between expert centers (>15 F/BEVAR per year) and nonexpert centers (≤15 F/BEVAR per year).

Results

Ninety-seven patients from 28 centers were treated. Aneurysms types included juxta-renal and short neck (84.6%), pararenal (5.2%), paravisceral (3.1%), and type IV thoracoabdominal (2.5%). Configurations with 1, 2, 3, and 4 fenestrations were used in 2, 12, 18, and 65 cases, respectively, totaling 350 TVs. Technical success was 98.0%, with 1 type Ic and 1 type IIIc endoleak. Mean follow-up was 468 days. Ten patients died, with 8 deaths (8.2%) due to non-aortic causes and 2 deaths (2.1%) from unknown causes. The estimated 1-year survival rate was 92.7% (95% CI: 87.8-98.1%). The reintervention rate at 30 days was 11.3% and the estimated reintervention rate at 1 year was 21.6% (95% CI: 12.7-29.6%). No type Ia endoleak occurred during follow-up. Three type III endoleaks occurred and required reintervention. Three TV occlusion occurred, yielding a 1-year TVI-free rate of 92.4% (95% CI: 89.4-99.3). No device-related major complication was recorded, and 3 device-related AEs occurred: 1 limb migration, 1 limb kinking and 1 limb thrombosis. There was no statistically significant difference in mortality and survival without reintervention between expert and nonexpert centers (Log rank p=0.52 and p=0.16, respectively).

Conclusion

The fenestrated Anaconda device demonstrated acceptable early and at 1-year safety and efficacy for treating primarily juxta-renal and short-neck aortic aneurysms, in centers with varying levels of experience. Clinical Impact The Anaconda Fenestrated, as the second commercially available custom-made device for complex endovascular aortic surgery, might adress some anatomical challenges. Following market authorization, this registry presents the 1-year outcomes of real-world device usage in a large number of centers, including small clinics. The results indicate that the device provided adequate efficacy and safety for treating mostly juxta-renal and short neck aneurysms, with notable improvement in technical success rate compared to older reports.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Vessel ProsthesisEndovascular ProceduresBlood Vessel Prosthesis ImplantationStentsAortic Aneurysm, AbdominalHumansMaleFemaleAgedRegistriesProsthesis DesignTime FactorsFranceAged, 80 and overTreatment OutcomeRisk FactorsProspective StudiesPostoperative ComplicationsRisk AssessmentMiddle AgedEndoleakEndovascular Aneurysm Repair

Stichwörter der Autor:innen

anacondaaneurysmaorticcomplexendovascularfenestratedjuxta-renal

Autor:innen und Institutionen

  • Vascular Surgery Department, Hopital Louis Pradel, Hospices Civils de Lyon, Bron, France.
  • Hôpital Privé de Villeneuve d'Ascq, Villeneuve d'Ascq, France.
  • Hopital Robert Schuman, Metz, France.
  • Centre Hospitalier Universitaire Nord, Marseille, France.
  • Centre Hospitalier Universitaire Timone, Marseille, France.
  • Centre Hospitalier Universitaire Pellegrin, Bordeaux, France.

ORCID-Profile: Alexandre Oliny

Zitieren

APA

Oliny, A., Vasseur, M. A., Frisch, N., Alimi, Y., Omnes, V., Ducasse, E., Albertini, J. N., & Millon, A. (2026). Fenestrated Endovascular Aortic Repair of Complex Aneurysm Using the Anaconda Fenestrated Device: 1-Year Results From the French Multicenter Registry. Journal of Endovascular Therapy. https://doi.org/10.1177/15266028241284034

Vancouver

Oliny A, Vasseur MA, Frisch N, Alimi Y, Omnes V, Ducasse E, et al. Fenestrated Endovascular Aortic Repair of Complex Aneurysm Using the Anaconda Fenestrated Device: 1-Year Results From the French Multicenter Registry. Journal of Endovascular Therapy. 2026. doi:10.1177/15266028241284034

BibTeX
@article{Oliny2026,
  author = {Oliny, Alexandre and Vasseur, Marc-Antoine and Frisch, Nicolas and Alimi, Yves and Omnes, Virgile and Ducasse, Eric and Albertini, Jean-Noël and Millon, Antoine},
  title = {Fenestrated Endovascular Aortic Repair of Complex Aneurysm Using the Anaconda Fenestrated Device: 1-Year Results From the French Multicenter Registry},
  journal = {Journal of Endovascular Therapy},
  year = {2026},
  doi = {10.1177/15266028241284034}
}
Kostenlos starten →