EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Early Results and Feasibility of Total Endovascular Aortic Arch Repair Using 3-Vessel Company-Manufactured and Physician-Modified Stent-Grafts

K Benjamin Lee iD, Jesus Porras-Colon, Carla K Scott, Khalil Chamseddin, Mirza S Baig, Carlos H Timaran

Journal of Endovascular Therapy · 2024-12 · 31 (6) · 1197-1207

DOI: 10.1177/15266028231163069 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Endovascular Therapy, online erschienen am 28.03.2023. Verfasst von K Benjamin Lee und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Vascular and Endovascular Surgery, Department of Surgery, The University of Texas Southwestern Medical Center, Dallas, TX, USA. Hauptthemen laut MEDLINE: Feasibility Studies, Endovascular Procedures, Blood Vessel Prosthesis, Stents. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Total endovascular repair of aortic arch aneurysms is feasible in select patients. This study aims to evaluate the feasibility and early outcomes of total endovascular arch repair using 3-vessel company-manufactured devices (CMDs) and physician-modified endo grafts (PMEGs).

Methods

Patients unfit for open repair who underwent 3-vessel total arch repair at a single institution from 2018 to 2021 were reviewed. Patients received either 3-vessel inner-branch CMDs or PMEGs. Three-vessel designs were used to incorporate the innominate, left common carotid, and left subclavian arteries. The antegrade inner branches in both devices were accessed via right brachial or carotid approach. The left carotid was accessed via carotid cutdown or femoral approach. The left subclavian artery was accessed via transfemoral approach. The study endpoints included procedural technical success, patient survival, neurologic events, cardiac complications, reinterventions, and target artery patency.

Results

Nine patients underwent treatment. Four patients were treated with PMEGs, and 5 with CMDs. Procedural technical success was 100%. There were no in-hospital deaths. There were no strokes, transient ischemic attacks, myocardial infarction, or spinal ischemia in the perioperative period. Major adverse events occurred in 3 patients (33%). Two (22%) vascular access complications and one (11%) acute kidney injury occurred. One (11%) patient required early reintervention for an access complication. The median follow-up period was 358 days (CMD, 392 days; PMEG, 198 days). There was a late reintervention and conversion to open repair at 142 days of follow-up in a patient with a PMEG that developed an aortic infection, leading to death on postoperative day 239. The mean length of stay was 7±4 days. Computed tomography imaging obtained during the immediate postoperative period revealed endoleak in 6 (66%) patients, out of which 5 resolved spontaneously and 1 required reintervention via left subclavian artery stenting. Target artery patency was 100% at the end of the follow-up period.

Conclusions

Three-vessel total endovascular aortic arch repair using a CMD or PMEG is feasible with optimal early outcomes. Physician-modified stent-grafts are a feasible option for patients who do not meet anatomic criteria for CMDs. Clinical Impact Management of aortic arch disease remains a significant challenge in vascular surgery. This study showcases the feasibility and safety of using a total endovascular approach to repair the aortic arch, which could potentially reduce morbidity and mortality associated with traditional surgical approaches. The results suggest that this minimally invasive technique could be an alternative treatment option for high-risk patients and could significantly improve outcomes for those requiring aortic arch repair. Overall, this study represents a promising development in the field of endovascular surgery and highlights the potential to improve patient outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Feasibility StudiesEndovascular ProceduresBlood Vessel ProsthesisStentsBlood Vessel Prosthesis ImplantationProsthesis DesignAortic Aneurysm, ThoracicPostoperative ComplicationsHumansMaleAgedTreatment OutcomeFemaleTime FactorsRetrospective StudiesAged, 80 and overRisk FactorsMiddle AgedVascular PatencyAorta, Thoracic

Stichwörter der Autor:innen

aortic archaortic arch aneurysmaortic arch dissectionendovascular aneurysm repairthoracic endovascular aortic repair

Autor:innen und Institutionen

  • Division of Vascular and Endovascular Surgery, Department of Surgery, The University of Texas Southwestern Medical Center, Dallas, TX, USA.

ORCID-Profile: K Benjamin Lee

Zitieren

APA

Lee, K. B., Porras-Colon, J., Scott, C. K., Chamseddin, K., Baig, M. S., & Timaran, C. H. (2024). Early Results and Feasibility of Total Endovascular Aortic Arch Repair Using 3-Vessel Company-Manufactured and Physician-Modified Stent-Grafts. Journal of Endovascular Therapy, 31(6), 1197-1207. https://doi.org/10.1177/15266028231163069

Vancouver

Lee KB, Porras-Colon J, Scott CK, Chamseddin K, Baig MS, Timaran CH. Early Results and Feasibility of Total Endovascular Aortic Arch Repair Using 3-Vessel Company-Manufactured and Physician-Modified Stent-Grafts. Journal of Endovascular Therapy. 2024;31(6):1197-1207. doi:10.1177/15266028231163069

BibTeX
@article{Lee2024,
  author = {Lee, K Benjamin and Porras-Colon, Jesus and Scott, Carla K and Chamseddin, Khalil and Baig, Mirza S and Timaran, Carlos H},
  title = {Early Results and Feasibility of Total Endovascular Aortic Arch Repair Using 3-Vessel Company-Manufactured and Physician-Modified Stent-Grafts},
  journal = {Journal of Endovascular Therapy},
  year = {2024},
  volume = {31},
  number = {6},
  pages = {1197--1207},
  doi = {10.1177/15266028231163069}
}
Kostenlos starten →