EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

The one-minute sit-to-stand test: A practical tool for assessing functional exercise capacity in patients with COPD in routine clinical practice

Paulien Mellaerts iD, Heleen Demeyer, Astrid Blondeel, Tim Vanhoutte, Sofie Breuls iD, Marieke Wuyts, Iris Coosemans, Lode Claes, Nele Vandenbergh, Kaat Beckers, Lucas Vanden Bossche, Dimitri Stylemans und 3 weitere

Chronic Respiratory Disease · 2024-01 · 21

DOI: 10.1177/14799731241291530 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Chronic Respiratory Disease, online erschienen am 14.10.2024. Verfasst von Paulien Mellaerts und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Sciences, KU Leuven, Leuven, Belgium. Hauptthemen laut MEDLINE: Pulmonary Disease, Chronic Obstructive, Exercise Tolerance, Exercise Test, Walk Test. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Chronic obstructive pulmonary disease (COPD) is associated with a reduced exercise capacity. Although several field tests for exercise capacity have been modified for non-standard settings, i.e. outside the hospital clinic or pulmonary rehabilitation center, their uptake remains limited.

Objectives

To assess the test-retest reliability, constuct validity and responsiveness of the one-minute sit-to-stand test (1′STST) adopted in clinical practice among patients with COPD and to confirm the earlier established minimal important difference (MID) of three repetitions.

Methods

Patients with COPD performed two 1′STSTs, two 6-minute walk tests (6MWT), an isometric quadriceps force (QF) measurement, a cardiopulmonary exercise test (CPET), and a seven-day physical activity (PA) measurement before and after three months of pulmonary rehabilitation (PR). An Intraclass Correlation Coefficient (ICC) evaluated the agreement between two 1′STSTs. Pearson Correlation examined the association between the 1′STST and other physical measurements, and their changes following PR. A receiver operating characteristic (ROC) curve was constructed using a 30-meter increment in the 6MWT as cut-off to identify responders.

Results

The 1′STST demonstrated good reliability (Δ0.9 ± 4.0 repetitions, p = .13; ICC = 0.79). The 1′STST was moderately correlated with the 6MWT (r = 0.57, p < .0001), VO 2 max (r = 0.50, p = .0006) and maximal work rate (r = 0.52, p = .0003). Weak correlations were observed with QF (r = 0.33, p = .03) and step count (r = 0.38, p = .013). The 1′STST improved after PR (∆ = 3.6 ± 6.4 repetitions, p = .0013) and changes correlated moderately with changes in the 6MWT (r = 0.57, p = .002), QF (r = 0.48, p = .003) and VO 2 max (r = 0.41, p = .014). A cut-off of three repetitions demonstrated a 71% accuracy in identifying responders to a rehabilitation program.

Conclusion

The 1′STST is a valuable alternative to evaluate exercise capacity in patients with COPD when more expensive and time-consuming tests are unavailable.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary Disease, Chronic ObstructiveExercise ToleranceExercise TestWalk TestHumansMaleFemaleAgedReproducibility of ResultsMiddle AgedQuadriceps MuscleROC CurveMuscle StrengthMinimal Clinically Important Difference

Stichwörter der Autor:innen

COPDclinical practiceexercise capacityone-minute sit-to-stand testpulmonary rehabilitationrespiratory diseasevalidity

Autor:innen und Institutionen

  • Department of Rehabilitation Sciences, KU Leuven, Leuven, Belgium.
  • Department of Rehabilitation Sciences, Ghent University, Ghent, Belgium.
  • IS Global, Barcelona, Spain.
  • Respiratory division, University Hospitals Leuven, Leuven, Belgium.
  • Department of Psychology, KU Leuven, Leuven, Belgium.
  • Clinical department of Respiratory diseases, UZ Leuven- BREATHE, department CHROMETA, KU Leuven, Leuven, Belgium.

ORCID-Profile: Paulien Mellaerts, Sofie Breuls

Zitieren

APA

Mellaerts, P., Demeyer, H., Blondeel, A., Vanhoutte, T., Breuls, S., Wuyts, M., Coosemans, I., Claes, L., Vandenbergh, N., Beckers, K., Bossche, L. V., Stylemans, D., Janssens, W., Everaerts, S., & Troosters, T. (2024). The one-minute sit-to-stand test: A practical tool for assessing functional exercise capacity in patients with COPD in routine clinical practice. Chronic Respiratory Disease, 21. https://doi.org/10.1177/14799731241291530

Vancouver

Mellaerts P, Demeyer H, Blondeel A, Vanhoutte T, Breuls S, Wuyts M, et al. The one-minute sit-to-stand test: A practical tool for assessing functional exercise capacity in patients with COPD in routine clinical practice. Chronic Respiratory Disease. 2024;21. doi:10.1177/14799731241291530

BibTeX
@article{Mellaerts2024,
  author = {Mellaerts, Paulien and Demeyer, Heleen and Blondeel, Astrid and Vanhoutte, Tim and Breuls, Sofie and Wuyts, Marieke and Coosemans, Iris and Claes, Lode and Vandenbergh, Nele and Beckers, Kaat and Bossche, Lucas Vanden and Stylemans, Dimitri and Janssens, Wim and Everaerts, Stephanie and Troosters, Thierry},
  title = {The one-minute sit-to-stand test: A practical tool for assessing functional exercise capacity in patients with COPD in routine clinical practice},
  journal = {Chronic Respiratory Disease},
  year = {2024},
  volume = {21},
  doi = {10.1177/14799731241291530}
}
Kostenlos starten →