Hybrid CAE-DSVDD for unsupervised vibration-based damage detection in in situ steel truss bridge
Structural Health Monitoring · 2026-11 · 25 (6) · 4176-4199
DOI: 10.1177/14759217251369727 ↗Kurz gefasst
Fachartikel in der Zeitschrift Structural Health Monitoring, online erschienen am 12.09.2025. Verfasst von Soyeon Park und 1 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: National Research Foundation of Korea.
Abstract (Originalsprache)
Recent advances in deep learning have enhanced vibration-based damage detection in civil infrastructure. However, the limited availability of labeled damage data remains a major obstacle for real-world deployment. To address this, this study proposes a novel unsupervised anomaly detection framework that relies solely on vibration data from intact structures. The framework integrates a convolutional autoencoder (CAE) with deep support vector data description (DSVDD), combining reconstruction-based and one-class classification approaches to improve sensitivity to subtle damage-induced changes. Time–frequency features are first extracted using the Fourier Synchrosqueezed Transform, which is transformed into images that amplify damage-sensitive patterns. The CAE-DSVDD model, tailored for multisensor structural health monitoring data under real-world operational conditions, is trained exclusively on undamaged-state data. A damage index is then computed by combining reconstruction error and latent-space deviation. Model performance is optimized through hyperparameter tuning, including a balancing parameter between the dual objectives. Unsupervised thresholds are evaluated to enable label-free classification. The framework is validated using field monitoring data from a real-world damaged truss bridge, demonstrating its high detection accuracy to real-world datasets. Additional experiments assess the framework’s robustness under varying loading conditions, input representations, sensor configurations, and its potential for damage localization. The proposed method achieved an F1-score of 98.46% under forced vibration, with consistent performance across low-severity damage cases. The overall results indicate the proposed framework provides an effective solution for unsupervised structural damage detection, offering a scalable and data-efficient approach for real-world infrastructure monitoring.
Förderung
- National Research Foundation of Korea
Zitieren
APA
Park, S., & Kim, S. (2026). Hybrid CAE-DSVDD for unsupervised vibration-based damage detection in in situ steel truss bridge. Structural Health Monitoring, 25(6), 4176-4199. https://doi.org/10.1177/14759217251369727
Vancouver
Park S, Kim S. Hybrid CAE-DSVDD for unsupervised vibration-based damage detection in in situ steel truss bridge. Structural Health Monitoring. 2026;25(6):4176-4199. doi:10.1177/14759217251369727
BibTeX
@article{Park2026,
author = {Park, Soyeon and Kim, Sunjoong},
title = {Hybrid CAE-DSVDD for unsupervised vibration-based damage detection in in situ steel truss bridge},
journal = {Structural Health Monitoring},
year = {2026},
volume = {25},
number = {6},
pages = {4176--4199},
doi = {10.1177/14759217251369727}
}