RFIS-HI: a new health indicator for quantitative condition monitoring of the bearing under variable speed conditions
Structural Health Monitoring · 2024-07 · 23 (4) · 2407-2422
DOI: 10.1177/14759217231203244 ↗Kurz gefasst
Fachartikel in der Zeitschrift Structural Health Monitoring, online erschienen am 07.11.2023. Verfasst von Weipeng Ma und 4 weiteren Autor:innen. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
The health indicator (HI) plays a crucial role in the condition monitoring of the rolling bearing. However, most existing HIs exhibit significant fluctuations when the speed changes. To address the issue, this paper proposes a new HI namely reweighted fault impact strength (RFIS)-HI. First, sub-signals are obtained through a frequency division strategy, and corresponding resampled signals are derived using order tracking. Second, the average impact peak in the time domain is acquired to measure the impact of the signal. According to fault characteristic order (FCO), the ratio of FCOs summation to noise amplitude in the frequency domain is obtained to measure periodicity. Then, the FISgram is constructed for selecting the optimal frequency band. To better quantify the degradation degree of the bearing, different weights are assigned and optimized for constructing RFIS. Finally, the influence of rotational speed on RFIS is eliminated by utilizing prior knowledge. Taking the first 10% of the dataset as baseline data, RFIS-HI is constructed through relative similarity. In this paper, a bearing dataset under time-varying speed conditions and an XJTU-SY dataset are used for verification. Results show that the proposed HI can achieve better trendability, scale similarity, and stability.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Ma, W., Yu, Y., Guo, L., Qian, M., & Gao, H. (2024). RFIS-HI: a new health indicator for quantitative condition monitoring of the bearing under variable speed conditions. Structural Health Monitoring, 23(4), 2407-2422. https://doi.org/10.1177/14759217231203244
Vancouver
Ma W, Yu Y, Guo L, Qian M, Gao H. RFIS-HI: a new health indicator for quantitative condition monitoring of the bearing under variable speed conditions. Structural Health Monitoring. 2024;23(4):2407-2422. doi:10.1177/14759217231203244
BibTeX
@article{Ma2024,
author = {Ma, Weipeng and Yu, Yaoxiang and Guo, Liang and Qian, Mengui and Gao, Hongli},
title = {RFIS-HI: a new health indicator for quantitative condition monitoring of the bearing under variable speed conditions},
journal = {Structural Health Monitoring},
year = {2024},
volume = {23},
number = {4},
pages = {2407--2422},
doi = {10.1177/14759217231203244}
}