Method for determination of elemental impurities in metronidazole benzoate using inductively coupled plasma mass spectrometry

Maoxian Tian, Hui Zhang, Huajun Fan, Mingxing Yin, Wenqing Wang, Chunyang Shi iD

European Journal of Mass Spectrometry · 2024

DOI: 10.1177/14690667231211696 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Mass Spectrometry, 2024. Verfasst von Maoxian Tian und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. Hauptthemen laut MEDLINE: Metronidazole, Drug Contamination. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The elemental impurities in pharmaceutical products have aroused widespread concern among respective supervising authorities and official pharmacopoeias since they are harmful and have no therapeutic effects. Metronidazole benzoate is used extensively to treat a variety of infections. However, impurities will inevitably be introduced in the manufacturing process of metronidazole benzoate. Hence, in this study, a sensitive method was developed for trace determination of elemental impurities in metronidazole benzoate active pharmaceutical ingredients by using inductively coupled plasma mass spectrometry in kinetic energy discrimination mode. The method was validated for system suitability, specificity, linearity, sensitivity, accuracy, and precision according to USP chapter Elemental Impurities-Procedure. The method had good linearity with correlation coefficients > 0.99. The limits of detection were in the range of 0.0003–0.1411 μg/g, which was lower than the acceptable limit and indicated the high sensitivity of the method. The method was accurate with the recoveries in the range of 92%–107%. Moreover, the content of seven elemental impurities in the three batches of metronidazole benzoate active pharmaceutical ingredients by this method was originally below their limits and less than 30% of permitted daily exposure, meeting the requirement of International Council for Harmonization Q3D guidelines. Thus, this newly developed and validated method for estimating elemental impurities in metronidazole benzoate active pharmaceutical ingredients was within the permitted limit and suitable for routine use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MetronidazoleDrug ContaminationMass SpectrometrySpectrum AnalysisBenzoatesPharmaceutical Preparations

Stichwörter der Autor:innen

International Council for Harmonization Q3D guidelinesMetronidazole benzoateUSP chapterelemental impuritiesinductively coupled plasma mass spectrometry

Substanzen

MetronidazoleBenzoatesPharmaceutical Preparations

Autor:innen und Institutionen

  • Department of Pharmacy, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
  • Hainan Center for Drug and Medical Device Evaluation and Service, Haikou, China.
  • ICAS Testing Technology Service (Shanghai) Co., Ltd, Shanghai, China.

ORCID-Profile: Chunyang Shi

Zitieren

APA

Tian, M., Zhang, H., Fan, H., Yin, M., Wang, W., & Shi, C. (2024). Method for determination of elemental impurities in metronidazole benzoate using inductively coupled plasma mass spectrometry. European Journal of Mass Spectrometry. https://doi.org/10.1177/14690667231211696

Vancouver

Tian M, Zhang H, Fan H, Yin M, Wang W, Shi C. Method for determination of elemental impurities in metronidazole benzoate using inductively coupled plasma mass spectrometry. European Journal of Mass Spectrometry. 2024. doi:10.1177/14690667231211696

BibTeX
@article{Tian2024,
  author = {Tian, Maoxian and Zhang, Hui and Fan, Huajun and Yin, Mingxing and Wang, Wenqing and Shi, Chunyang},
  title = {Method for determination of elemental impurities in metronidazole benzoate using inductively coupled plasma mass spectrometry},
  journal = {European Journal of Mass Spectrometry},
  year = {2024},
  doi = {10.1177/14690667231211696}
}
Kostenlos starten →