EUVIMEDEUVIMED entdecken
Crossref

Dipole and quadrupole resonance excitation in linear quadrupoles

N V Konenkov iD

European Journal of Mass Spectrometry · 2024-02 · 30 (1) · 3-37

DOI: 10.1177/14690667231204359 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Mass Spectrometry, online erschienen am 11.10.2023. Verfasst von N V Konenkov. Beteiligte Einrichtung: Ryazan State University, Ryazan, Russia. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 79 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the development of commercial quadrupole mass spectrometers, there is an interest in improving the performance characteristics such as transmission, resolution, and mass range. In particular, parametric and dipolar resonance excitation of trapping ions are used for linear quadrupole mass filters. Theoretical methods and numerical simulation of ion trajectories were applied for study of ion-optical properties. The review is devoted to description of different excitation methods to improve QMF performance and consists of three parts. The first part presents the results of a linear ion trap simulation for various operating conditions and excitation methods. The second part considers the effects of dipole excitation (DE) on the performance of the quadrupole mass filter. The last part analyzes the formation of stability islands by different methods of quadrupole excitation. To date conditions of mass separation in quadrupole mass filters with sin wave supply were described for stability islands of the first and third stability regions formed by quadrupole and DE. By complicating the electronics such methods allow to overcome the destructive influence of electric field distortions and obtain a resolving power and ion transmission efficiency comparable with commercial devices. At quadrupole resonance excitation by a two-frequency signal, it is possible to reduce the length of electrodes three times without losses in resolution and transmission, which reduces the cost of rod set production with micrometer accuracy. Dipole resonance excitation allows controlling the shape of the mass peak by changing amplitude and phase of the auxiliary AC signal. The main factors affecting the resolving power of a linear ion trap are described theoretically. The numerical modeling results are confirmed by experiment.

Schlagwörter

Stichwörter der Autor:innen

Linear ion trapdipole excitationexcitation timeparametric resonancequadrupole excitationquadrupole mass filterstability islands

Autor:innen und Institutionen

  • Ryazan State University, Ryazan, Russia.

ORCID-Profile: N V Konenkov

Zitieren

APA

Konenkov, N. V. (2024). Dipole and quadrupole resonance excitation in linear quadrupoles. European Journal of Mass Spectrometry, 30(1), 3-37. https://doi.org/10.1177/14690667231204359

Vancouver

Konenkov NV. Dipole and quadrupole resonance excitation in linear quadrupoles. European Journal of Mass Spectrometry. 2024;30(1):3-37. doi:10.1177/14690667231204359

BibTeX
@article{Konenkov2024,
  author = {Konenkov, N V},
  title = {Dipole and quadrupole resonance excitation in linear quadrupoles},
  journal = {European Journal of Mass Spectrometry},
  year = {2024},
  volume = {30},
  number = {1},
  pages = {3--37},
  doi = {10.1177/14690667231204359}
}
Kostenlos starten →