Mechanical characterization of auxetic chiral-reentrant cellular metamaterials: A finite element study
Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications · 17.08.2026
DOI: 10.1177/14644207261477971 ↗Kurz gefasst
Fachartikel in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications, online erschienen am 17.08.2026. Verfasst von Guoji Wang und 3 weiteren Autor:innen. Die Arbeit nennt 55 Literaturangaben. Gefördert von: Industry-University Cooperation Collaborative Education Project of the Ministry of Education, Shangqiu Municipal Science and Technology Research Project, Henan Provincial Science and Technology Research Project.
Abstract (Originalsprache)
This study investigates the mechanical behavior of a novel tubular auxetic metamaterial combining chiral (rotation-dominated) and reentrant (hinging) mechanisms in a hybrid “Circle-I” design. The sole design variable was the internal extrusion thickness (the difference between external and internal diameters), varied across five configurations from 1 mm to 9 mm in odd increments. Finite element simulations under quasi-static axial compression were used to evaluate load-displacement response, stiffness, energy absorption (EA), specific energy absorption (SEA), and structural negative Poisson's ratio (NPR). Results showed strong thickness dependence: increasing internal thickness significantly enhanced conventional mechanical properties, with peak force reaching 917 N in the 9 mm configuration at smaller displacements, stiffness rising from 18 N/mm to 598 N/mm, and energy absorption increasing from 50 J for the thinnest configuration to 1496 J for the thickest. In contrast, NPR exhibited a non-monotonic trend, becoming more negative (from −1.5 to a peak of −1.8) as thickness increased from 1 mm to 5 mm, before dropping to −1.0 at 9 mm. This non-monotonic behavior highlights an optimal intermediate thickness for maximum auxeticity via efficient chiral-reentrant coupling. Experimental validation confirmed the numerical predictions. The findings demonstrate that internal thickness is an effective single-parameter control for tailoring multifunctional performance in tubular chiral-reentrant metamaterials, with potential applications in impact protection, biomedical devices, and lightweight structures.
Förderung
- Industry-University Cooperation Collaborative Education Project of the Ministry of Education
- Shangqiu Municipal Science and Technology Research Project
- Henan Provincial Science and Technology Research Project
Zitieren
APA
Wang, G., Zhang, W., Wang, Y., & Zhang, M. (2026). Mechanical characterization of auxetic chiral-reentrant cellular metamaterials: A finite element study. Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications. https://doi.org/10.1177/14644207261477971
Vancouver
Wang G, Zhang W, Wang Y, Zhang M. Mechanical characterization of auxetic chiral-reentrant cellular metamaterials: A finite element study. Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications. 2026. doi:10.1177/14644207261477971
BibTeX
@article{Wang2026,
author = {Wang, Guoji and Zhang, Weijie and Wang, Yanhua and Zhang, Maohuan},
title = {Mechanical characterization of auxetic chiral-reentrant cellular metamaterials: A finite element study},
journal = {Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications},
year = {2026},
doi = {10.1177/14644207261477971}
}
EUVIMED