EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A variable step-size FxLMS algorithm for active vibration control of cantilever beam

Jinhua Jiang, Xiaoyan Chen, Yihan Yan, Zimei Tu, Qian Wang

Journal of Low Frequency Noise, Vibration and Active Control · 17.07.2026

DOI: 10.1177/14613484261470208 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Low Frequency Noise, Vibration and Active Control, online erschienen am 17.07.2026. Verfasst von Jinhua Jiang und 4 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The conventional filtered-x least mean square (FxLMS) algorithm for active vibration control (AVC) is limited by the trade-off between convergence rate and steady-state error and by its sensitivity to abrupt input changes. To address these issues, a nonlinear step-size adjustment mechanism combining a bounded hyperbolic tangent mapping with a normalized variable step-size strategy is developed, based on which a variable step-size FxLMS algorithm, termed VSS-FxtanhLMS, is proposed. The convergence properties of the algorithm are analyzed in the mean and mean-square senses. For AVC of a flexible cantilever beam, the proposed algorithm is evaluated on a co-simulation platform established using ADAMS and Simulink under single-frequency, dual-frequency, and amplitude-step excitations, and is further validated on an experimental AVC platform. Co-simulation results show that VSS-FxtanhLMS achieves the smallest steady-state error, the lowest mean squared error, and the shortest convergence time under both single-frequency and dual-frequency excitations, while remaining convergent under amplitude-step excitation. In experiments, compared with FxasinhLMS, the strongest competing method, VSS-FxtanhLMS reduces the steady-state error by 17.48%, shortens the convergence time by 33.33%, and reduces the power spectral density by 1.72 dB/Hz. These results indicate that VSS-FxtanhLMS achieves improved steady-state accuracy, convergence behavior, and robustness under both simulation and practical conditions.

Zitieren

APA

Jiang, J., Chen, X., Yan, Y., Tu, Z., & Wang, Q. (2026). A variable step-size FxLMS algorithm for active vibration control of cantilever beam. Journal of Low Frequency Noise, Vibration and Active Control. https://doi.org/10.1177/14613484261470208

Vancouver

Jiang J, Chen X, Yan Y, Tu Z, Wang Q. A variable step-size FxLMS algorithm for active vibration control of cantilever beam. Journal of Low Frequency Noise, Vibration and Active Control. 2026. doi:10.1177/14613484261470208

BibTeX
@article{Jiang2026,
  author = {Jiang, Jinhua and Chen, Xiaoyan and Yan, Yihan and Tu, Zimei and Wang, Qian},
  title = {A variable step-size FxLMS algorithm for active vibration control of cantilever beam},
  journal = {Journal of Low Frequency Noise, Vibration and Active Control},
  year = {2026},
  doi = {10.1177/14613484261470208}
}