EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Easy-to-use and easy-to-interpret quality control of 3D gradient echo T1-weighted MR acquisition sequences for improved test-retest stability of MRI-based hippocampus volumetry

Ralph Buchert iD, Per Suppa, Babak A Ardekani, Fuensanta Bellvís Bataller, Pierrick Bourgeat, Pierrick Coupé, Robert Dahnke, Gabriel A Devenyi iD, Simon Fristed Eskildsen, Clara Fischer, Jose Vincente Manjón Herrera, Christian Ledig und 7 weitere

Journal of Alzheimer’s Disease · 2025

DOI: 10.1177/13872877251380301 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Alzheimer’s Disease, 2025. Verfasst von Ralph Buchert und 18 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany. Hauptthemen laut MEDLINE: Hippocampus, Magnetic Resonance Imaging, Imaging, Three-Dimensional. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 103 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

MRI-based hippocampus volume (HV) is widely used as neurodegeneration marker in Alzheimer's disease.

Objective

An easy-to-use and easy-to-interpret method to categorize T1-weighted MR sequences with respect to test-retest stability of hippocampus volumetry based on general image quality metrics (IQM).

Methods

The study included 446 3D T1-weighted MRI scans of one healthy middle-aged man obtained during 32 months in 122 scanning sessions performed with 96 different scanners at 76 different sites. Each scanning session represented a different acquisition sequence of ≥2 back-to-back repeat scans (3.7 ± 0.7 on average). Unilateral HVs were determined with 18 different tools for automatic volumetry. An acquisition sequence was considered “poor” if the z-score of the within-session coefficient-of-variation of the HV estimates from the session, averaged across all volumetry tools and both hemispheres, exceeded one standard deviation. General IQM were computed for each scanning session using the freely available MRI Quality Control Tool. A classification-and-regression tree (CART) was trained to discriminate between good and poor acquisition sequences using the IQM as input.

Results

The CART selected the left-right width of the acquisition field-of-view and the contrast-to-noise ratio as predictor variables. Overall accuracy of the CART was 79.5%. CART-based classification increased the ratio of good-to-poor acquisition sequences from 3.5 among all sequences to 7.4 among the sequences predicted to be good. This was at the expense of losing 15% of the good sequences.

Conclusions

The IQM-based decision tree model provides useful performance for the differentiation of T1-weighted sequences associated with good versus poor test-retest stability of hippocampus volumetry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HippocampusMagnetic Resonance ImagingImaging, Three-DimensionalHumansMaleMiddle AgedQuality ControlAdultReproducibility of ResultsOrgan SizeImage Processing, Computer-Assisted

Stichwörter der Autor:innen

Alzheimer's diseaseclassification-and-regression treecontrast-to-noise ratiofield-of-viewhippocampusimage qualityoutlierstructural MRIvolumetry

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Olympus Winter & Ibe GmbH, Hamburg, Germany.
  • Center for Brain Imaging and Neuromodulation, The Nathan S. Kline Institute for Psychiatric Research, Orangeburg, NY, USA.
  • Quantitative Imaging Biomarkers in Medicine (Quibim), Valencia, Spain.
  • Australian e-Health Research Centre, CSIRO Health and Biosecurity, Brisbane, Australia.
  • LaBRI - UMR 5800, University of Bordeaux, Talence, France.

ORCID-Profile: Ralph Buchert, Gabriel A Devenyi

Zitieren

APA

Buchert, R., Suppa, P., Ardekani, B. A., Bellvís Bataller, F., Bourgeat, P., Coupé, P., Dahnke, R., Devenyi, G. A., Eskildsen, S. F., Fischer, C., Manjón Herrera, J. V., Ledig, C., Lemke, A., Maréchal, B., Opfer, R., Sima, D. M., Spies, L., Ulug, A. M., & Huppertz, H. J. (2025). Easy-to-use and easy-to-interpret quality control of 3D gradient echo T1-weighted MR acquisition sequences for improved test-retest stability of MRI-based hippocampus volumetry. Journal of Alzheimer’s Disease. https://doi.org/10.1177/13872877251380301

Vancouver

Buchert R, Suppa P, Ardekani BA, Bellvís Bataller F, Bourgeat P, Coupé P, et al. Easy-to-use and easy-to-interpret quality control of 3D gradient echo T1-weighted MR acquisition sequences for improved test-retest stability of MRI-based hippocampus volumetry. Journal of Alzheimer’s Disease. 2025. doi:10.1177/13872877251380301

BibTeX
@article{Buchert2025,
  author = {Buchert, Ralph and Suppa, Per and Ardekani, Babak A and Bellvís Bataller, Fuensanta and Bourgeat, Pierrick and Coupé, Pierrick and Dahnke, Robert and Devenyi, Gabriel A and Eskildsen, Simon Fristed and Fischer, Clara and Manjón Herrera, Jose Vincente and Ledig, Christian and Lemke, Andreas and Maréchal, Bénédicte and Opfer, Roland and Sima, Diana M and Spies, Lothar and Ulug, Aziz M and Huppertz, Hans-Jürgen},
  title = {Easy-to-use and easy-to-interpret quality control of 3D gradient echo T1-weighted MR acquisition sequences for improved test-retest stability of MRI-based hippocampus volumetry},
  journal = {Journal of Alzheimer’s Disease},
  year = {2025},
  doi = {10.1177/13872877251380301}
}
Kostenlos starten →