Rapid cognitive assessment: Accuracy and discriminant validity of Mini-Cog and process-based Clock Drawing Test
Journal of Alzheimer’s Disease · 2025
DOI: 10.1177/13872877251314788 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Alzheimer’s Disease, 2025. Verfasst von Qian Yang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Geriatric Endocrinology, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China. Hauptthemen laut MEDLINE: Cognitive Dysfunction, Alzheimer Disease, Neuropsychological Tests, Mental Status and Dementia Tests. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shanghai Municipal Science and Technology Major Project.
Abstract (Originalsprache)
Background
The Mini-Cog is a brief cognitive examination comprising a three-item memory recall and a simplified Clock Drawing Test (CDT). There is limited research on the effects of detailed scoring criteria for the Mini-Cog on cognitive screening.
Objective
To assess the diagnostic effectiveness of three Mini-Cog versions and a new process-based CDT test in identifying mild cognitive impairment (MCI) and Alzheimer's disease (AD) compared to cognitively normal controls (NC).
Methods
We prospectively enrolled 950 subjects who underwent standardized neuropsychological assessments and the Mini-Cog test. The CDT was scored using an adapted 10-point scale. The accuracy of three Mini-Cog versions (Mini-Cog1: 3-word delayed recall + 2-point CDT; Mini-Cog2: 3-word immediate recall + 3-word delayed recall + 3-point CDT; Mini-Cog3: 3-word immediate recall + 3-word delayed recall + 10-point CDT) was assessed through the receiver operating characteristic analysis. Sensitivity and specificity were determined for each diagnostic threshold.
Results
The optimal cut-off point for Mini-Cog3 is 12/16 for MCI and 10/16 for AD. Mini-Cog3 demonstrated the highest diagnostic efficacy, with AUCs of 0.82 (95% CI: 0.78–0.85) for MCI and 0.95 (95% CI: 0.94–0.97) for AD, with sensitivity of 85% for both MCI and AD. The CDT's AUCs were 0.77 (95% CI: 0.73–0.81) for MCI, and 0.87 (95% CI: 0.84–0.90) for AD, with sensitivity of 89% for MCI, and 82% for AD.
Conclusions
A more elaborate scoring system, such as Mini-Cog3, may serve as an effective screening method for the rapid and accurate detection of cognitive dysfunction in patients with MCI and AD.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Geriatric Endocrinology, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China.
- Department of Gerontology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China.
ORCID-Profile: Qian Yang, Hao Yang, Wei Long, Sheng Zuo, Defa Zhu, Qihao Guo
Förderung
- National Natural Science Foundation of China
- Shanghai Municipal Science and Technology Major Project
Zitieren
APA
Yang, Q., Yang, H., Long, W., Zuo, S., Zhu, D., & Guo, Q. (2025). Rapid cognitive assessment: Accuracy and discriminant validity of Mini-Cog and process-based Clock Drawing Test. Journal of Alzheimer’s Disease. https://doi.org/10.1177/13872877251314788
Vancouver
Yang Q, Yang H, Long W, Zuo S, Zhu D, Guo Q. Rapid cognitive assessment: Accuracy and discriminant validity of Mini-Cog and process-based Clock Drawing Test. Journal of Alzheimer’s Disease. 2025. doi:10.1177/13872877251314788
BibTeX
@article{Yang2025,
author = {Yang, Qian and Yang, Hao and Long, Wei and Zuo, Sheng and Zhu, Defa and Guo, Qihao},
title = {Rapid cognitive assessment: Accuracy and discriminant validity of Mini-Cog and process-based Clock Drawing Test},
journal = {Journal of Alzheimer’s Disease},
year = {2025},
doi = {10.1177/13872877251314788}
}
EUVIMED