Analysis of eye movement features in patients with Alzheimer's disease based on intelligent eye movement analysis and evaluation system
Journal of Alzheimer’s Disease · 2024
DOI: 10.1177/13872877241297416 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Alzheimer’s Disease, 2024. Verfasst von Meichun Tao und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, The Second Hospital of Hebei Medical University, Shijiazhuang, China. Hauptthemen laut MEDLINE: Alzheimer Disease, Cognitive Dysfunction, Eye Movements. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 38 Literaturangaben.
Themen: Demenz
Abstract (Originalsprache)
Background
The early identification of Alzheimer's disease (AD) benefits patients, so creating a simple and convenient method is crucial for diagnosing early symptoms.
Objective
To offer a potential approach for the early detection of both AD and mild cognitive impairment (MCI).
Methods
Eye movement data from 66 patients were divided into three groups, including healthy control group (HC), MCI group, and AD group. We searched for parameters that can detect MCI at an early stage and drew receiver operating characteristic (ROC) curves. The correlation between eye movement parameters and cognitive scores was analyzed.
Results
The MCI group differed from the HC group in error correction rate of antisaccade ( p = 0.008) and total offset degrees (>4°) ( p = 0.011) of lateral fixation. The AD group had different overlap prosaccade accuracy ( p = 0.025), latency ( p = 0.009) and average completion time ( p = 0.015), gap prosaccade latency ( p = 0.005) and average completion time ( p = 0.005), antisaccade accuracy ( p = 0.006), error correction rate ( p < 0.001) and average saccade velocity ( p = 0.035), and lateral fixation accuracy ( p = 0.018), total offset degrees (>4°) ( p = 0.041) compared to the HC group. The AD group differed significantly from the MCI group in accuracy ( p = 0.001) and error correction rate ( p = 0.044) of antisaccades, the latency ( p = 0.009) and average completion time ( p = 0.025) of overlap prosaccade and the latency ( p = 0.038) of gap prosaccade, these parameters can serve as indicators to monitor the progress of the disease. Lateral fixation combined with antisaccade was more conducive to identifying MCI patients with the area under the ROC curve of 0.837. Most eye movement parameters had a light to moderate correlation with cognitive scores.
Conclusions
Eye movements can be used for early identification of MCI/AD patients and to monitor disease progression.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurology, The Second Hospital of Hebei Medical University, Shijiazhuang, China.
- The Key Laboratory of Clinical Neurology (Hebei Medical University), Ministry of Education, Shijiazhuang, Hebei, China.
- Neurological Laboratory of Hebei Province, Shijiazhuang, Hebei, China.
ORCID-Profile: Meichun Tao, Yuanyuan Du, Mei Dong
Zitieren
APA
Tao, M., Cui, L., Du, Y., Liu, X., Wang, C., Zhao, J., Qiao, H., Li, Z., & Dong, M. (2024). Analysis of eye movement features in patients with Alzheimer's disease based on intelligent eye movement analysis and evaluation system. Journal of Alzheimer’s Disease. https://doi.org/10.1177/13872877241297416
Vancouver
Tao M, Cui L, Du Y, Liu X, Wang C, Zhao J, et al. Analysis of eye movement features in patients with Alzheimer's disease based on intelligent eye movement analysis and evaluation system. Journal of Alzheimer’s Disease. 2024. doi:10.1177/13872877241297416
BibTeX
@article{Tao2024,
author = {Tao, Meichun and Cui, Lei and Du, Yuanyuan and Liu, Xiaotang and Wang, Can and Zhao, Jing and Qiao, Huimin and Li, Zhenzhong and Dong, Mei},
title = {Analysis of eye movement features in patients with Alzheimer's disease based on intelligent eye movement analysis and evaluation system},
journal = {Journal of Alzheimer’s Disease},
year = {2024},
doi = {10.1177/13872877241297416}
}
EUVIMED