Intraoperative monitoring of malignant liver tumor microwave ablation using contrast-enhanced ultrasound: A preliminary study

Ivor Dropco iD, Nina Käser, Ulrich Kaiser, Paul Kupke, Hans Jürgen Schlitt, Stefan M Brunner, Christina Hackl, Christian Stroszczynski, Ernst Michael Jung

Clinical Hemorheology and Microcirculation · 2026-12 · 94 (1-2) · 32-39

DOI: 10.1177/13860291261491824 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Hemorheology and Microcirculation, online erschienen am 28.09.2026. Verfasst von Ivor Dropco und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, University Hospital Regensburg, Regensburg, Germany. Hauptthemen laut MEDLINE: Liver Neoplasms, Microwaves, Contrast Media, Monitoring, Intraoperative. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study aimed to evaluate intraoperative assessment and monitoring of liver tumor ablations using contrast-enhanced ultrasound (CEUS).

Methods

Twenty patients (11 males [65%] and 9 females [45%]) with malignant lesions (cholangiocellular carcinoma (CCC), 1; hepatocellular carcinoma (HCC), 5; colorectal liver metastases (CRLM), 13; and one patient with alveolar echinococcosis) were examined intraoperatively with CEUS. Images were acquired in cine loops, covering the early arterial phase (0–15 s) up to the portal venous phase (1 min). Ablation was performed under real-time ultrasound guidance using microwave ablation (MWA). The generator output was adjusted up to 80 watts, up to 10 min. Post-ablation CEUS was conducted for immediate control.

Results

Twenty patients underwent ablation procedures. Ablation was carried out under ultrasound guidance with adjusted output settings between 40 and 80 watts and durations ranging from 2 to 5 min. Post-interventional CEUS confirmed complete devascularization in all planes. All patients underwent track ablation using 70 watts. At 6-month follow-up, no local recurrence was observed.

Conclusion

The preliminary findings demonstrate the feasibility of intraoperative CEUS during microwave ablation of liver lesions. The technique proves to be a safe and effective intraoperative tool, owing to its ability to provide verification of complete tumor devascularization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Liver NeoplasmsMicrowavesContrast MediaMonitoring, IntraoperativeCatheter AblationHumansFemaleMaleUltrasonographyMiddle AgedAgedCarcinoma, Hepatocellular

Stichwörter der Autor:innen

Intraoperative CEUScontrast enhancement in liver lesionsdynamic vascularizationintraoperative microwave ablation (MWA)intraoperative monitoringliver surgeryliver tumorsmicrobubblesmicrocirculationultrasound of the liver

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Surgery, University Hospital Regensburg, Regensburg, Germany.
  • ÜBAG Dr. Vehling-Kaiser MVZ GmbH, Landshut, Germany.
  • Interdisciplinary Ultrasound Department, Institute of Diagnostic Radiology, University Hospital Regensburg, Regensburg, Germany.

ORCID-Profile: Ivor Dropco

Zitieren

APA

Dropco, I., Käser, N., Kaiser, U., Kupke, P., Schlitt, H. J., Brunner, S. M., Hackl, C., Stroszczynski, C., & Jung, E. M. (2026). Intraoperative monitoring of malignant liver tumor microwave ablation using contrast-enhanced ultrasound: A preliminary study. Clinical Hemorheology and Microcirculation, 94(1-2), 32-39. https://doi.org/10.1177/13860291261491824

Vancouver

Dropco I, Käser N, Kaiser U, Kupke P, Schlitt HJ, Brunner SM, et al. Intraoperative monitoring of malignant liver tumor microwave ablation using contrast-enhanced ultrasound: A preliminary study. Clinical Hemorheology and Microcirculation. 2026;94(1-2):32-39. doi:10.1177/13860291261491824

BibTeX
@article{Dropco2026,
  author = {Dropco, Ivor and Käser, Nina and Kaiser, Ulrich and Kupke, Paul and Schlitt, Hans Jürgen and Brunner, Stefan M and Hackl, Christina and Stroszczynski, Christian and Jung, Ernst Michael},
  title = {Intraoperative monitoring of malignant liver tumor microwave ablation using contrast-enhanced ultrasound: A preliminary study},
  journal = {Clinical Hemorheology and Microcirculation},
  year = {2026},
  volume = {94},
  number = {1-2},
  pages = {32--39},
  doi = {10.1177/13860291261491824}
}
Kostenlos starten →