Intraoperative monitoring of malignant liver tumor microwave ablation using contrast-enhanced ultrasound: A preliminary study
Clinical Hemorheology and Microcirculation · 2026-12 · 94 (1-2) · 32-39
DOI: 10.1177/13860291261491824 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Hemorheology and Microcirculation, online erschienen am 28.09.2026. Verfasst von Ivor Dropco und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, University Hospital Regensburg, Regensburg, Germany. Hauptthemen laut MEDLINE: Liver Neoplasms, Microwaves, Contrast Media, Monitoring, Intraoperative. Die Arbeit nennt 25 Literaturangaben.
Abstract (Originalsprache)
Objective
This study aimed to evaluate intraoperative assessment and monitoring of liver tumor ablations using contrast-enhanced ultrasound (CEUS).
Methods
Twenty patients (11 males [65%] and 9 females [45%]) with malignant lesions (cholangiocellular carcinoma (CCC), 1; hepatocellular carcinoma (HCC), 5; colorectal liver metastases (CRLM), 13; and one patient with alveolar echinococcosis) were examined intraoperatively with CEUS. Images were acquired in cine loops, covering the early arterial phase (0–15 s) up to the portal venous phase (1 min). Ablation was performed under real-time ultrasound guidance using microwave ablation (MWA). The generator output was adjusted up to 80 watts, up to 10 min. Post-ablation CEUS was conducted for immediate control.
Results
Twenty patients underwent ablation procedures. Ablation was carried out under ultrasound guidance with adjusted output settings between 40 and 80 watts and durations ranging from 2 to 5 min. Post-interventional CEUS confirmed complete devascularization in all planes. All patients underwent track ablation using 70 watts. At 6-month follow-up, no local recurrence was observed.
Conclusion
The preliminary findings demonstrate the feasibility of intraoperative CEUS during microwave ablation of liver lesions. The technique proves to be a safe and effective intraoperative tool, owing to its ability to provide verification of complete tumor devascularization.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Surgery, University Hospital Regensburg, Regensburg, Germany.
- ÜBAG Dr. Vehling-Kaiser MVZ GmbH, Landshut, Germany.
- Interdisciplinary Ultrasound Department, Institute of Diagnostic Radiology, University Hospital Regensburg, Regensburg, Germany.
ORCID-Profile: Ivor Dropco
Zitieren
APA
Dropco, I., Käser, N., Kaiser, U., Kupke, P., Schlitt, H. J., Brunner, S. M., Hackl, C., Stroszczynski, C., & Jung, E. M. (2026). Intraoperative monitoring of malignant liver tumor microwave ablation using contrast-enhanced ultrasound: A preliminary study. Clinical Hemorheology and Microcirculation, 94(1-2), 32-39. https://doi.org/10.1177/13860291261491824
Vancouver
Dropco I, Käser N, Kaiser U, Kupke P, Schlitt HJ, Brunner SM, et al. Intraoperative monitoring of malignant liver tumor microwave ablation using contrast-enhanced ultrasound: A preliminary study. Clinical Hemorheology and Microcirculation. 2026;94(1-2):32-39. doi:10.1177/13860291261491824
BibTeX
@article{Dropco2026,
author = {Dropco, Ivor and Käser, Nina and Kaiser, Ulrich and Kupke, Paul and Schlitt, Hans Jürgen and Brunner, Stefan M and Hackl, Christina and Stroszczynski, Christian and Jung, Ernst Michael},
title = {Intraoperative monitoring of malignant liver tumor microwave ablation using contrast-enhanced ultrasound: A preliminary study},
journal = {Clinical Hemorheology and Microcirculation},
year = {2026},
volume = {94},
number = {1-2},
pages = {32--39},
doi = {10.1177/13860291261491824}
}
EUVIMED