EUVIMEDEUVIMED entdecken
Crossref

Experimental investigation of steel bolted T-Stub connections at different post-fire conditions

Mahyar Maali, Zeynep Yaman, Elif Ağcakoca, Mohammad Saber Sadid, Abdulkadir Cüneyt Aydın, Hüsna Ekşi

Advances in Structural Engineering · 16.07.2026

DOI: 10.1177/13694332261459973 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advances in Structural Engineering, online erschienen am 16.07.2026. Verfasst von Mahyar Maali und 5 weiteren Autor:innen. Die Arbeit nennt 44 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The main factor in the collapse of steel structures is the bearing capacity of beam-column connections. One of the most common connection types for steel structures is the T stub connection. The bearing capacity of these connections is affected by loads such as earthquakes and fire. Therefore, in this study, the fire effect and the high-temperature value at the T connection were investigated to examine their effects on the behavior of the connection zone. The study was conducted using 15 T-Stub connections. T-Stub bolted joints examined in the study were produced using IPE standard profiles. Three cross-sections were used, with t f /t w ratios of 1.52, 1.56, and 1.58. The test elements formed using prestressed bolts of the same diameter were examined at four high temperatures. In the first part of the study, the behavior of 15 T-Stub connections under axial tensile loading was experimentally determined. The second part created a finite element model in ABAQUS for all models. The finite element model analysis results converged with those from the experimental study, with an average 2% error in maximum load-carrying capacity and 11% in energy dissipation capacity. As the t f /t w ratio increased, the F max capacity increased, while the deformation capacity decreased. While no significant loss of cross-section stiffness was observed up to 600°C, significant stiffness loss was observed at 900°C.

Zitieren

APA

Maali, M., Yaman, Z., Ağcakoca, E., Sadid, M. S., Aydın, A. C., & Ekşi, H. (2026). Experimental investigation of steel bolted T-Stub connections at different post-fire conditions. Advances in Structural Engineering. https://doi.org/10.1177/13694332261459973

Vancouver

Maali M, Yaman Z, Ağcakoca E, Sadid MS, Aydın AC, Ekşi H. Experimental investigation of steel bolted T-Stub connections at different post-fire conditions. Advances in Structural Engineering. 2026. doi:10.1177/13694332261459973

BibTeX
@article{Maali2026,
  author = {Maali, Mahyar and Yaman, Zeynep and Ağcakoca, Elif and Sadid, Mohammad Saber and Aydın, Abdulkadir Cüneyt and Ekşi, Hüsna},
  title = {Experimental investigation of steel bolted T-Stub connections at different post-fire conditions},
  journal = {Advances in Structural Engineering},
  year = {2026},
  doi = {10.1177/13694332261459973}
}
Kostenlos starten →