The Finger Dexterity Test: Validation study of a smartphone-based manual dexterity assessment
Multiple Sclerosis Journal · 2024
DOI: 10.1177/13524585231216007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Multiple Sclerosis Journal, 2024. Verfasst von Delphine Van Laethem und 12 weiteren Autor:innen. Beteiligte Einrichtung: AIMS Lab, Center for Neurosciences, UZ Brussel, Vrije Universiteit Brussel, Brussel, Belgium. Hauptthemen laut MEDLINE: Fingers, Multiple Sclerosis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Agentschap Innoveren en Ondernemen, Fonds Wetenschappelijk Onderzoek, CLAIMS project: Innovative Health Initiative Joint Undertaking.
Abstract (Originalsprache)
Background
The Nine-Hole Peg Test (9HPT) is the golden standard to measure manual dexterity in people with multiple sclerosis (MS). However, administration requires trained personnel and dedicated time during a clinical visit.
Objectives
The objective of this study is to validate a smartphone-based test for remote manual dexterity assessment, the icompanion Finger Dexterity Test (FDT), to be included into the icompanion application.
Methods
A total of 65 MS and 81 healthy subjects were tested, and 20 healthy subjects were retested 2 weeks later.
Results
The FDT significantly correlated with the 9HPT (dominant: ρ = 0.62, p < 0.001; non-dominant: ρ = 0.52, p < 0.001). MS subjects had significantly higher FDT scores than healthy subjects (dominant: p = 0.015; non-dominant: p = 0.013), which was not the case for the 9HPT. A significant correlation with age (dominant: ρ = 0.46, p < 0.001; non-dominant: ρ = 0.40, p = 0.002), Expanded Disability Status Scale (EDSS, dominant: ρ = 0.36, p = 0.005; non-dominant: ρ = 0.31, p = 0.024), and disease duration for the non-dominant hand (ρ = 0.31, p = 0.016) was observed. There was a good test–retest reliability in healthy subjects (dominant: r = 0.69, p = 0.001; non-dominant: r = 0.87, p < 0.001).
Conclusions
The icompanion FDT shows a moderate-to-good concurrent validity and test–retest reliability, differentiates between the MS subjects and healthy controls, and correlates with clinical parameters. This test can be implemented into routine MS care for remote follow-up of manual dexterity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- AIMS Lab, Center for Neurosciences, UZ Brussel, Vrije Universiteit Brussel, Brussel, Belgium.
- Department of Physical and Rehabilitation Medicine, UZ Brussel, Brussel, Belgium.
- AIMS Lab, Center for Neurosciences, UZ Brussel, Vrije Universiteit Brussel, Brussel, Belgium/icometrix, Leuven, Belgium.
- icometrix, Leuven, Belgium.
- Neurology Department, National Multiple Sclerosis Center, Melsbroek, Belgium.
- Neurology Department, UZ Brussel, Brussel, Belgium.
ORCID-Profile: Delphine Van Laethem, Stijn Denissen, Johan Baijot, Miguel D'Haeseleer
Förderung
- Agentschap Innoveren en Ondernemen
- Fonds Wetenschappelijk Onderzoek
- CLAIMS project: Innovative Health Initiative Joint Undertaking
Zitieren
APA
Van Laethem, D., Denissen, S., Costers, L., Descamps, A., Baijot, J., Van Remoortel, A., Van Merhaegen-Wieleman, A., D'hooghe, M. B., D'Haeseleer, M., Smeets, D., Sima, D. M., Van Schependom, J., & Nagels, G. (2024). The Finger Dexterity Test: Validation study of a smartphone-based manual dexterity assessment. Multiple Sclerosis Journal. https://doi.org/10.1177/13524585231216007
Vancouver
Van Laethem D, Denissen S, Costers L, Descamps A, Baijot J, Van Remoortel A, et al. The Finger Dexterity Test: Validation study of a smartphone-based manual dexterity assessment. Multiple Sclerosis Journal. 2024. doi:10.1177/13524585231216007
BibTeX
@article{VanLaethem2024,
author = {Van Laethem, Delphine and Denissen, Stijn and Costers, Lars and Descamps, Annabel and Baijot, Johan and Van Remoortel, Ann and Van Merhaegen-Wieleman, Annick and D'hooghe, Marie B and D'Haeseleer, Miguel and Smeets, Dirk and Sima, Diana M and Van Schependom, Jeroen and Nagels, Guy},
title = {The Finger Dexterity Test: Validation study of a smartphone-based manual dexterity assessment},
journal = {Multiple Sclerosis Journal},
year = {2024},
doi = {10.1177/13524585231216007}
}
EUVIMED