EUVIMEDEUVIMED entdecken
Crossref

First in-human feasibility evaluation of an integrated guidewire Seldinger system with enhanced ultrasound feedback for central venous access

Thomas J Allen, Vikram R Shaw, Adrian Ebner, Edgar Lopez, Juan Castellano, Marco Caballero, Hernan Rebolledo, Paul A Sobotka

The Journal of Vascular Access · 04.11.2026

DOI: 10.1177/11297298261498464 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Vascular Access, online erschienen am 04.11.2026. Verfasst von Thomas J Allen und 7 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Gefördert von: South53.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Central venous access procedures are among the most frequently performed invasive procedures worldwide, yet they remain associated with measurable complication rates and technical challenges. Despite the widespread adoption of ultrasound guidance, limitations in needle visualization, needle stability and workflow inefficiencies persist.

Methods

This study presents the first in-human feasibility evaluation of an integrated guidewire Seldinger-based central venous access system with enhanced echogenic feedback. Three experienced physicians performed central venous access on forty patients using the Seldinger-based 510k-approved Primero device vascular access system under ultrasound guidance.

Results

The device demonstrated a procedural success rate of 97.5%, a successful first attempt placement rate of 95%, and a median time from skin puncture to guidewire placement of 103.5 s. Physicians reported qualitatively improved visualization, ease of use, enhanced control, and reduced hand transitions, which improved workflow during vascular access.

Conclusions

These findings support feasibility and justify further controlled prospective evaluation.

Förderung

  • South53

Zitieren

APA

Allen, T. J., Shaw, V. R., Ebner, A., Lopez, E., Castellano, J., Caballero, M., Rebolledo, H., & Sobotka, P. A. (2026). First in-human feasibility evaluation of an integrated guidewire Seldinger system with enhanced ultrasound feedback for central venous access. The Journal of Vascular Access. https://doi.org/10.1177/11297298261498464

Vancouver

Allen TJ, Shaw VR, Ebner A, Lopez E, Castellano J, Caballero M, et al. First in-human feasibility evaluation of an integrated guidewire Seldinger system with enhanced ultrasound feedback for central venous access. The Journal of Vascular Access. 2026. doi:10.1177/11297298261498464

BibTeX
@article{Allen2026,
  author = {Allen, Thomas J and Shaw, Vikram R and Ebner, Adrian and Lopez, Edgar and Castellano, Juan and Caballero, Marco and Rebolledo, Hernan and Sobotka, Paul A},
  title = {First in-human feasibility evaluation of an integrated guidewire Seldinger system with enhanced ultrasound feedback for central venous access},
  journal = {The Journal of Vascular Access},
  year = {2026},
  doi = {10.1177/11297298261498464}
}
Kostenlos starten →