Transesophageal echocardiography-guided repositioning of a totally implantable venous access device that migrated into the left atrium across a patent foramen ovale
The Journal of Vascular Access · 2026-11 · 27 (6) · 2996-3000
DOI: 10.1177/11297298261475792 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Vascular Access, online erschienen am 18.08.2026. Verfasst von William Amaya-Zúñiga und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesia and Perioperative Medicine, Hospital Universitario Fundación Santa Fe de Bogotá, Bogotá, Colombia. Die Arbeit nennt 8 Literaturangaben.
Abstract (Originalsprache)
Migration of a totally implantable venous access port into the cardiac chambers can lead to a wide range of potentially serious complications. Malpositioned devices require thorough clinical assessment and timely intervention to minimize associated risks. We report the case of a patient whose catheter tip migrated across a patent foramen ovale into the left atrium. Because prompt surgical repositioning was required, conscious sedation and real-time transesophageal echocardiography were utilized to provide precise guidance. This approach enabled safe catheter withdrawal, accurate repositioning within the superior vena cava, and immediate confirmation of catheter function using a saline flush test.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesia and Perioperative Medicine, Hospital Universitario Fundación Santa Fe de Bogotá, Bogotá, Colombia.
- Department of Critical Care, Universidad del Rosario, Bogotá, Colombia.
- Department of Anesthesia and Perioperative Medicine, Universidad del Rosario, Bogotá, Colombia.
- Department of Surgery, Universidad de los Andes, Bogotá, Colombia.
- Department of Cardiology and Echocardiography Unit, Universidad de los Andes, Bogotá, Colombia.
ORCID-Profile: William Amaya-Zúñiga, María Cifuentes-Ortiz, Daniel Benítez-Ávila
Zitieren
APA
Amaya-Zúñiga, W., Cifuentes-Ortiz, M., Benítez-Ávila, D., Fajardo-Gómez, R., & Romero-Vanegas, N. (2026). Transesophageal echocardiography-guided repositioning of a totally implantable venous access device that migrated into the left atrium across a patent foramen ovale. The Journal of Vascular Access, 27(6), 2996-3000. https://doi.org/10.1177/11297298261475792
Vancouver
Amaya-Zúñiga W, Cifuentes-Ortiz M, Benítez-Ávila D, Fajardo-Gómez R, Romero-Vanegas N. Transesophageal echocardiography-guided repositioning of a totally implantable venous access device that migrated into the left atrium across a patent foramen ovale. The Journal of Vascular Access. 2026;27(6):2996-3000. doi:10.1177/11297298261475792
BibTeX
@article{AmayaZiga2026,
author = {Amaya-Zúñiga, William and Cifuentes-Ortiz, María and Benítez-Ávila, Daniel and Fajardo-Gómez, Roosevelt and Romero-Vanegas, Nohra},
title = {Transesophageal echocardiography-guided repositioning of a totally implantable venous access device that migrated into the left atrium across a patent foramen ovale},
journal = {The Journal of Vascular Access},
year = {2026},
volume = {27},
number = {6},
pages = {2996--3000},
doi = {10.1177/11297298261475792}
}
EUVIMED