EUVIMEDEUVIMED entdecken
Crossref

Correlation of right heart catheterization and duplex ultrasound to identify fistula volume flow

Enrico Prajiante Bertolino iD, Khan Abdullah, Cole Pickney, Jose Emanuel Finet, Wai Hong Wilson Tang, Ahmed A Sorour, Sean P Lyden, Lee Kirksey iD

The Journal of Vascular Access · 2026-11 · 27 (6) · 2867-2875

DOI: 10.1177/11297298261461907 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Vascular Access, online erschienen am 01.09.2026. Verfasst von Enrico Prajiante Bertolino und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular Surgery, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH, USA. Die Arbeit nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Arteriovenous fistula is the preferred form of hemodialysis access. Positive remodeling may result in high flow vascular access (HFVA), leading to elevated right heart pressures, cardiomyopathy and in advanced presentation-high-output heart failure (HOHF). Noninvasive duplex ultrasound (DUS) is the most commonly accepted mode of surveillance for HFVA. The reliability of DUS compared to the gold standard modality of right heart catheterization (RHC) to quantify access circuit volume flow (Qa) has not been reported. Our aim is to analyze a cohort of patients with suspected HOHF who underwent both studies and evaluate the concordance between Qa measurements.

Methods

We identified a consecutive cohort of eight patients with suspected HFVA and HOHF requiring diagnostic RHC. Qa was calculated by DUS and RHC. The association between the two measures was calculated using Pearson correlation, and agreement was assessed with Lin’s concordance correlation coefficient. We evaluate the association between brachial artery (BA) diameter and the Qa agreement.

Results

The mean Qa measured by DUS was 2623 ml/min, compared to a mean of 1538 ml/min measured by RHC. On average, the Qa measured by the DUS was 1086 ml/min greater than the RHC measurement, representing a 104% incremental difference. Only two of the eight cases (25%) had Qa measures within 500 ml/min. This discordance was greatest with a larger BA diameter, where a lower agreement measure of 0.39 and a moderate range correlation of 0.55 was found between Qa measured with RHC and DUS.

Conclusion

Although DUS is the most utilized modality to monitor Qa, low correlation is observed compared to RHC, discrepancy that is directly associated with BA diameter and may reflect true overestimation of Qa by DUS or result from measurements obtained under differing hemodynamic conditions (e.g. heart rate variability). RHC should be used more liberally for the diagnosis and management of HFVA, particularly when HOHF is suspected.

Schlagwörter

Stichwörter der Autor:innen

Arteriovenous fistuladuplex ultrasoundheart failureright heart catheterizationvascular access

Autor:innen und Institutionen

  • Department of Vascular Surgery, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH, USA.
  • Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, USA.
  • Miller Family Heart, Vascular & Thoracic Institute, Cleveland Clinic, Cleveland, OH, USA.

ORCID-Profile: Enrico Prajiante Bertolino, Lee Kirksey

Zitieren

APA

Prajiante Bertolino, E., Abdullah, K., Pickney, C., Finet, J. E., Tang, W. H. W., Sorour, A. A., Lyden, S. P., & Kirksey, L. (2026). Correlation of right heart catheterization and duplex ultrasound to identify fistula volume flow. The Journal of Vascular Access, 27(6), 2867-2875. https://doi.org/10.1177/11297298261461907

Vancouver

Prajiante Bertolino E, Abdullah K, Pickney C, Finet JE, Tang WHW, Sorour AA, et al. Correlation of right heart catheterization and duplex ultrasound to identify fistula volume flow. The Journal of Vascular Access. 2026;27(6):2867-2875. doi:10.1177/11297298261461907

BibTeX
@article{PrajianteBertolino2026,
  author = {Prajiante Bertolino, Enrico and Abdullah, Khan and Pickney, Cole and Finet, Jose Emanuel and Tang, Wai Hong Wilson and Sorour, Ahmed A and Lyden, Sean P and Kirksey, Lee},
  title = {Correlation of right heart catheterization and duplex ultrasound to identify fistula volume flow},
  journal = {The Journal of Vascular Access},
  year = {2026},
  volume = {27},
  number = {6},
  pages = {2867--2875},
  doi = {10.1177/11297298261461907}
}
Kostenlos starten →