Dialysis catheter insertion using Surfacer Inside-Out Access Catheter System in a heart transplant recipient
The Journal of Vascular Access · 2026-11 · 27 (6) · 2978-2982
DOI: 10.1177/11297298261461663 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Vascular Access, online erschienen am 07.07.2026. Verfasst von Angelie M Santos und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Nephrology, Department of Medicine, University of Wisconsin-Madison School of Medicine and Public Health, Madison, WI, USA. Die Arbeit nennt 10 Literaturangaben.
Abstract (Originalsprache)
Central venous occlusion (CVO) is a common complication in hemodialysis patients. The Surfacer Inside-Out Access Catheter System is designed to gain access through previously occluded right-sided central veins. We report a case of a 74-year-old heart transplant recipient with end stage kidney disease and multiple failed dialysis accesses who developed bilateral upper CVO and femoral catheter dependence and underwent right internal jugular re-canalization with Surfacer Inside-Out technology. To our knowledge, this is the first successful tunneled dialysis catheter (TDC) insertion using Surfacer technology in a heart transplant recipient. These patients are at risk of anastomotic stenoses as a complication after cardiac transplantation. This, coupled with the fact that long-term steroid use has been associated with vascular fragility, leads to increased risk of vascular complications in endovascular interventions. But in patients with exhausted vascular access from CVO, insertion of TDC with Surfacer technique is safe and feasible.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Nephrology, Department of Medicine, University of Wisconsin-Madison School of Medicine and Public Health, Madison, WI, USA.
ORCID-Profile: Angelie M Santos, Ali I Gardezi
Zitieren
APA
Santos, A. M., Chan, M. R., & Gardezi, A. I. (2026). Dialysis catheter insertion using Surfacer Inside-Out Access Catheter System in a heart transplant recipient. The Journal of Vascular Access, 27(6), 2978-2982. https://doi.org/10.1177/11297298261461663
Vancouver
Santos AM, Chan MR, Gardezi AI. Dialysis catheter insertion using Surfacer Inside-Out Access Catheter System in a heart transplant recipient. The Journal of Vascular Access. 2026;27(6):2978-2982. doi:10.1177/11297298261461663
BibTeX
@article{Santos2026,
author = {Santos, Angelie M and Chan, Micah R and Gardezi, Ali I},
title = {Dialysis catheter insertion using Surfacer Inside-Out Access Catheter System in a heart transplant recipient},
journal = {The Journal of Vascular Access},
year = {2026},
volume = {27},
number = {6},
pages = {2978--2982},
doi = {10.1177/11297298261461663}
}
EUVIMED