Feasibility study of ultrasound-guided, power-assisted needle insertion for hemodialysis cannulation using an innovative, handheld device
The Journal of Vascular Access · 2026-09 · 27 (5) · 2151-2156
DOI: 10.1177/11297298261437532 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Vascular Access, 2026-09. Verfasst von Patrick C Thompson und 6 weiteren Autor:innen. Beteiligte Einrichtung: Vascular Surgery, Connecticut Vascular Center, North Haven, CT, USA. Hauptthemen laut MEDLINE: Renal Dialysis, Ultrasonography, Interventional, Arteriovenous Shunt, Surgical, Needles. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 10 Literaturangaben.
Abstract (Originalsprache)
Background
Vascular access (VA) for hemodialysis is achieved through arteriovenous fistulas (AVF), arteriovenous grafts (AVG), or central venous access devices (CVAD). Hemodialysis remains the most common modality of kidney replacement therapy, and its continued success depends on the reliability and integrity of the patient’s vascular access. The current standard for assessing VA involves the “look, listen, and feel” method, which is highly dependent on the operator’s skill and experience. An innovative device has been developed to support the current approach by enabling machine-learning-trained, ultrasound-guided, power-assisted needle insertion for cannulation.
Objective
This first-in-human pilot study aimed to evaluate the feasibility of using the device to insert a single standard dialysis needle into the AVF of the arm prior to routine dialysis cannulation.
Methods
Patients receiving dialysis at a single institution over a 1-day period were recruited and consented to participate. Under operator control, the device was used to insert a needle into the AVF in preparation for a patient’s dialysis session. Unlike conventional ultrasound-guided techniques, the device enables operator alignment to the centerline of the AVF without requiring visual interpretation of ultrasound images using machine-learning-trained guidance. Observations related to safety and efficacy were recorded.
Results
A total of eight needle insertion attempts were performed in seven patients. In 6 of 7 procedures, the dialysis needle was successfully inserted into the AVF in the first attempt, confirmed by blood flashback. The first patient had two attempts without vessel entry, while the remaining six patients achieved successful access on the first attempt. No complications were reported.
Conclusions
The study demonstrates the feasibility of using an ultrasound-guided, power-assisted needle insertion device for vascular access in hemodialysis. These findings lay the groundwork for future studies using this innovative technology. This study is registered with the ISRCTN registry (ISRCTN22547122).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Vascular Surgery, Connecticut Vascular Center, North Haven, CT, USA.
- Palo Alto Medical Foundation for Health Care Research and Education, Mountain View, CA, USA.
- Department of Medicine (Nephrology), Stanford University School of Medicine, Stanford, CA, USA.
- Bluff City Vascular (Aligned with Lifeline Vascular Care), Memphis, TN, USA.
- Nano Medical Clinic, Olmazor District, Tashkent, Uzbekistan.
- Territorial Medical Association of Yangiyul District, Yangiyul District, Uzbekistan.
ORCID-Profile: Patrick C Thompson
Zitieren
APA
Thompson, P. C., McGlynn, P. K., Davis, O., Iskhakov, S., Mamayusupov, M., Madjitov, I., & Komolova, S. (2026). Feasibility study of ultrasound-guided, power-assisted needle insertion for hemodialysis cannulation using an innovative, handheld device. The Journal of Vascular Access. https://doi.org/10.1177/11297298261437532
Vancouver
Thompson PC, McGlynn PK, Davis O, Iskhakov S, Mamayusupov M, Madjitov I, et al. Feasibility study of ultrasound-guided, power-assisted needle insertion for hemodialysis cannulation using an innovative, handheld device. The Journal of Vascular Access. 2026. doi:10.1177/11297298261437532
BibTeX
@article{Thompson2026,
author = {Thompson, Patrick C and McGlynn, Patrick K and Davis, Omar and Iskhakov, Sherzod and Mamayusupov, Maratjon and Madjitov, Ibrogim and Komolova, Sakhiba},
title = {Feasibility study of ultrasound-guided, power-assisted needle insertion for hemodialysis cannulation using an innovative, handheld device},
journal = {The Journal of Vascular Access},
year = {2026},
doi = {10.1177/11297298261437532}
}
EUVIMED