Vergleichsstudie in der Zeitschrift The Journal of Vascular Access, 2025. Verfasst von Håkan Pärsson und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden. Hauptthemen laut MEDLINE: Needles, Catheterization, Central Venous, Catheters, Indwelling, Catheter-Related Infections. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Totally implantable venous access ports (TIVAPs) are essential for administering chemotherapeutic drugs and nutritional support, but carry a risk of infectious complications. We hypothesized that the design of the current port needle (Huber) could facilitate the collection of bacteria from the skin during puncture, potentially introducing them into TIVAPs and causing infections. This study examines bacterial transfer via needles during TIVAP access and proposes a novel needle design to reduce the risk of infection.

Methods

A novel needle, the Forsvall Port needle, was developed with a closed tip to reduce bacterial transmission inside the needle during tissue and port penetration. In a randomized ex vivo setting, human skin samples covered in physiological levels of Staphylococcus aureus were placed over port membranes and punctured repeatedly by the standard Huber needle and the Forsvall Port needle. Cultures from the needle tips were plated after puncture and used to compare bacterial transfer into TIVAPs using a generalized linear mixed-effects model. Punctures were performed in a separate human skin to examine the mechanism of bacterial transfer.

Results

The Forsvall Port needle reduced average bacterial transfer by 87.0% (95% CI: 77.8%–92.4%, p < 0.0001) compared with the Huber needle, based on 10 punctures per needle across four skin samples. Additional testing on a separate skin sample showed that a defectively fitted Forsvall Port needle prototype did not reduce bacterial transfer relative to the Huber needle (95% CI: 58.3% decrease to 30.0% increase, p = 0.289), whereas a steel rod simulating a perfectly closed Forsvall Port needle achieved a 99.9% (95% CI: 99.5%–100%, p < 0.0001) reduction in bacterial transfer.

Conclusion

The Forsvall Port needle significantly reduces bacterial transfer into TIVAPs, which could potentially decrease TIVAP-related infections. This study demonstrates a strong association between needle design and bacterial transfer during TIVAP access.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NeedlesCatheterization, Central VenousCatheters, IndwellingCatheter-Related InfectionsStaphylococcus aureusSkinEquipment ContaminationCentral Venous CathetersStaphylococcal InfectionsHumansEquipment DesignPunctures

Stichwörter der Autor:innen

CRBSIForsvall Port needleHuber needleTIVAPbacterial transfercatheter-related blood stream infectionex vivo studyinfection preventionsubcutaneous venous port

Autor:innen und Institutionen

  • Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
  • Department of Surgery, Kalmar Hospital, Kalmar, Sweden.
  • Faculty of Medicine, Department of Clinical Sciences, Infection Medicine, Lund University, Lund, Sweden.
  • Department of Urology, Helsingborg Hospital, Helsingborg, Sweden.
  • Department of Infectious Diseases, Helsingborg Hospital, Helsingborg, Sweden.
  • Faculty of Medicine, Department of Dermatology and Venereology, Lund University, Lund, Sweden.

ORCID-Profile: Håkan Pärsson, Magnus Wagenius, Maria Utter, Jonas Tverring, José Francisco Pereira Cardoso, Andreas Forsvall

Zitieren

APA

Pärsson, H., Wagenius, M., Utter, M., Tverring, J., Cardoso, J. F. P., & Forsvall, A. (2025). Addressing infection in totally implantable venous access ports: An ex vivo study on bacterial transfer and the Forsvall Port needle design. The Journal of Vascular Access. https://doi.org/10.1177/11297298251383741

Vancouver

Pärsson H, Wagenius M, Utter M, Tverring J, Cardoso JFP, Forsvall A. Addressing infection in totally implantable venous access ports: An ex vivo study on bacterial transfer and the Forsvall Port needle design. The Journal of Vascular Access. 2025. doi:10.1177/11297298251383741

BibTeX
@article{Prsson2025,
  author = {Pärsson, Håkan and Wagenius, Magnus and Utter, Maria and Tverring, Jonas and Cardoso, José Francisco Pereira and Forsvall, Andreas},
  title = {Addressing infection in totally implantable venous access ports: An ex vivo study on bacterial transfer and the Forsvall Port needle design},
  journal = {The Journal of Vascular Access},
  year = {2025},
  doi = {10.1177/11297298251383741}
}
Kostenlos starten →