Beobachtungsstudie in der Zeitschrift The Journal of Vascular Access, 2025. Verfasst von Francesco Tomeo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Azienda USL Toscana centro Sede di Empoli, Florence, Italy. Hauptthemen laut MEDLINE: Catheterization, Central Venous, Central Venous Catheters, Intensive Care Units, Catheters, Indwelling. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 10 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Centrally inserted central catheters (CICCs) are critical devices in intensive care settings, where patients often require life-saving therapies. However, the stability of these devices is essential to avoid dislodgement, migration, and therapy interruptions. Adhesive sutureless securements devices are challenging in terms of dislodgment rates, while sutures must be avoided. SAS (Subcutaneous anchored Securement Device) is widely used in Peripherally inserted central catheters (PICC) to reduce dislodgement rate and improve cost effectiveness, but its use in ICU is still limited.

Objective

To evaluate the incidence of CICC dislodgement using SAS in a second-level hospital ICU and assess whether its use increases catheter dwell time.

Methods

A prospective, observational, single-center study involving 100 ICU patients at high risk of CICC dislodgement was conducted. A total of 126 CICCs were placed and secured with SAS (SecurAcath), and outcomes were monitored.

Results

The dislodgement rate for SAS-CICCs was 4% (1.93 dislodgements per 1000 catheter days). The average catheter dwell time was 17.25 days, longer than adhesive securement devices (12.3 days). No device failures, local infections, or exit-site complications were reported.

Conclusion

SAS effectively stabilizes CICCs, reduces dislodgement rates, and extends catheter dwell time in high-risk ICU patients, aligning with 2024 GAVeCeLT guidelines.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheterization, Central VenousCentral Venous CathetersIntensive Care UnitsCatheters, IndwellingHumansPilot ProjectsProspective StudiesMaleFemaleMiddle AgedTime FactorsAgedEquipment DesignRisk FactorsAged, 80 and overAdultTreatment Outcome

Stichwörter der Autor:innen

CICCIntensive careSASDSecurAcathcentral venous access

Autor:innen und Institutionen

  • Azienda USL Toscana centro Sede di Empoli, Florence, Italy.

ORCID-Profile: Francesco Tomeo, Italo Calamai, Andrea Giannini

Zitieren

APA

Tomeo, F., Calamai, I., Luchini, M., Mori, I., Giannini, A., & Spina, R. (2025). Subcutaneous anchored securement of centrally inserted central catheter in intensive care unit: A pilot study. The Journal of Vascular Access. https://doi.org/10.1177/11297298251369060

Vancouver

Tomeo F, Calamai I, Luchini M, Mori I, Giannini A, Spina R. Subcutaneous anchored securement of centrally inserted central catheter in intensive care unit: A pilot study. The Journal of Vascular Access. 2025. doi:10.1177/11297298251369060

BibTeX
@article{Tomeo2025,
  author = {Tomeo, Francesco and Calamai, Italo and Luchini, Marco and Mori, Irene and Giannini, Andrea and Spina, Rosario},
  title = {Subcutaneous anchored securement of centrally inserted central catheter in intensive care unit: A pilot study},
  journal = {The Journal of Vascular Access},
  year = {2025},
  doi = {10.1177/11297298251369060}
}
Kostenlos starten →