Port REMoval Outcomes (PREMO) study: A pilot study for functional, microbial, radiological, and macroscopic assessment of totally implantable venous access devices

Thomas Douchy iD, Daphne Hompes, Geert Maleux iD, Martine Jérôme, Yorick Peeters, Godelieve Alice Goossens iD, Veerle Boecxstaens

The Journal of Vascular Access · 2026

DOI: 10.1177/11297298251335416 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Vascular Access, 2026. Verfasst von Thomas Douchy und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgical Oncology, University Hospitals Leuven, Leuven, Belgium. Hauptthemen laut MEDLINE: Catheters, Indwelling, Central Venous Catheters, Catheterization, Central Venous, Device Removal. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: b. braun medical.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

According to current guidelines Totally Implantable Venous Access Devices (TIVADs) require regular maintenance (i.e. flushing with 0.9% Sodium Chloride solution) when not in use. Existing evidence suggests that extending flushing intervals up to 12 weeks does not compromise catheter function, but longer intervals or omitting flushes require more research.

Methods

To facilitate a future randomized controlled trial (RCT), various methods were evaluated for assessing functional (CINAS classification, vacutainer filling time (VFT)), microbial (tip culture, swabs), radiological (linogram), and macroscopic (visual inspection) changes in TIVADs after a 12-weekly maintenance regimen. TIVADs from 70 patients were assessed upon TIVAD removal.

Results

Concerns over the perceived invasiveness of the linogram resulted in only 36% of eligible patients eventually consenting to participate in the trial. Eighty-six percent had normal TIVAD function, with an average VFT of 23 s/10 mL (SD 5 s/10 mL). Linograms were aberrant in 15% of patients, but the majority of anomalies did not correlate with visible thrombus on inspection or functional issues. No positive microbial cultures were found.

Conclusions

The primary end point of any future research on TIVAD maintenance should primarily be focused on the functionality of the TIVAD. The CINAS classification effectively standardizes reporting of TIVAD functionality. Although VFT offers a precise measurement of aspiration function, optimal target values remain unclear and clinical relevance might be limited in a functional TIVAD. The added value of a linogram seems to be negligible. An RCT trial comparing 12-weekly TIVAD maintenance versus no maintenance would be invaluable for both patients and health care providers. Clinical Trials register (NCT03948958).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheters, IndwellingCentral Venous CathetersCatheterization, Central VenousDevice RemovalCatheter-Related InfectionsHumansPilot ProjectsMaleFemaleMiddle AgedTime FactorsAgedTreatment OutcomePredictive Value of TestsAdultTherapeutic IrrigationEquipment DesignAged, 80 and over

Stichwörter der Autor:innen

CINAS scoreTIVADTIVAD maintenancelinogramvacutainer filling time

Autor:innen und Institutionen

  • Department of Surgical Oncology, University Hospitals Leuven, Leuven, Belgium.
  • Department of Interventional Radiology, University Hospitals Leuven, Leuven, Belgium.
  • Department of Surgical Oncology and Competence Centre of Nursing, University Hospitals Leuven, Leuven, Belgium.
  • Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium.

ORCID-Profile: Thomas Douchy, Geert Maleux, Godelieve Alice Goossens

Förderung

  • b. braun medical

Zitieren

APA

Douchy, T., Hompes, D., Maleux, G., Jérôme, M., Peeters, Y., Goossens, G. A., & Boecxstaens, V. (2026). Port REMoval Outcomes (PREMO) study: A pilot study for functional, microbial, radiological, and macroscopic assessment of totally implantable venous access devices. The Journal of Vascular Access. https://doi.org/10.1177/11297298251335416

Vancouver

Douchy T, Hompes D, Maleux G, Jérôme M, Peeters Y, Goossens GA, et al. Port REMoval Outcomes (PREMO) study: A pilot study for functional, microbial, radiological, and macroscopic assessment of totally implantable venous access devices. The Journal of Vascular Access. 2026. doi:10.1177/11297298251335416

BibTeX
@article{Douchy2026,
  author = {Douchy, Thomas and Hompes, Daphne and Maleux, Geert and Jérôme, Martine and Peeters, Yorick and Goossens, Godelieve Alice and Boecxstaens, Veerle},
  title = {Port REMoval Outcomes (PREMO) study: A pilot study for functional, microbial, radiological, and macroscopic assessment of totally implantable venous access devices},
  journal = {The Journal of Vascular Access},
  year = {2026},
  doi = {10.1177/11297298251335416}
}
Kostenlos starten →