EUVIMEDEUVIMED entdecken
Validierungsstudie

Development and validation of a tool for ambulatory monitoring of peripherally inserted central catheter-associated complications

Sofie Segers, Jodie Langbeen iD, Stijn Blot, Wim Terryn, Mieke Debrauwere, Dirk Vogelaers

The Journal of Vascular Access · 2026

DOI: 10.1177/11297298241305731 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift The Journal of Vascular Access, 2026. Verfasst von Sofie Segers und 5 weiteren Autor:innen. Beteiligte Einrichtung: General Practitioners Society, Ieper, Belgium. Hauptthemen laut MEDLINE: Catheterization, Peripheral, Catheterization, Central Venous, Central Venous Catheters, Catheter-Related Infections. Die Arbeit nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Peripherally inserted central catheters (PICC) are the preferred vascular access for Outpatient Parenteral Antimicrobial Therapy (OPAT) due to user-friendliness and high safety level. Nevertheless, the lack of a validated tool hampers the yet ill-charted epidemiology and monitoring of PICC related complications in ambulatory care.

Methods

A sequential exploratory mixed-method three phase research design was used to develop and validate a monitoring tool for PICC complications in OPAT. A literature review and co-design approach allowed its development, followed by Delphi panel content validation. In a third phase, the tool was piloted and implemented for further evaluation, including adherence.

Results

Twelve and nine experts respectively participated in the first and second Delphi round (response rate: 92% resp. 69%). Scale-level Content Validity Index based on the Average Method was 0.99 and 0.90 in the first and the second Delphi round respectively. After the Delphi procedure, the tool consisted of the following relevant items: (1) functionality (injection and aspiration), (2) insertion site, (3) catheter fixation, (4) infection and (5) thrombosis. After positive pilot testing, the tool was implemented in 17 participants with outcomes measured in 15 participants. Two participants were readmitted and three experienced PICC complications. As for adherence, the monitoring tool was partially or fully completed 285 times (74,8%); external catheter length was rarely or never reported and systematic follow-up of the temperature scored poorly.

Conclusion

A tool for ambulatory monitoring of PICC-associated complications with a solid content validity was obtained. Future research should consist of a multicentric larger size assessment and digitalization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheterization, PeripheralCatheterization, Central VenousCentral Venous CathetersCatheter-Related InfectionsCatheters, IndwellingAmbulatory CareMonitoring, AmbulatoryHumansDelphi TechniqueReproducibility of ResultsPredictive Value of TestsConsensusPilot ProjectsRisk FactorsMaleInfusions, ParenteralFemale

Stichwörter der Autor:innen

Central Line Associated Blood Stream InfectionsOutpatient Parenteral Antimicrobial Therapyambulatory carehome nursingperipherally inserted central catheter

Autor:innen und Institutionen

  • General Practitioners Society, Ieper, Belgium.
  • Department of General Internal Medicine and Infectious Diseases, Jan Yperman Hospital, Ieper, Belgium.
  • Department of General Internal Medicine and Infectious Diseases, AZ Delta, Roeselare, Belgium.
  • Department of Internal Medicine and Pediatrics, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium.
  • Department of Thoracic and Vascular Surgery, Ghent University Hospital, Ghent, Belgium.

ORCID-Profile: Jodie Langbeen

Zitieren

APA

Segers, S., Langbeen, J., Blot, S., Terryn, W., Debrauwere, M., & Vogelaers, D. (2026). Development and validation of a tool for ambulatory monitoring of peripherally inserted central catheter-associated complications. The Journal of Vascular Access. https://doi.org/10.1177/11297298241305731

Vancouver

Segers S, Langbeen J, Blot S, Terryn W, Debrauwere M, Vogelaers D. Development and validation of a tool for ambulatory monitoring of peripherally inserted central catheter-associated complications. The Journal of Vascular Access. 2026. doi:10.1177/11297298241305731

BibTeX
@article{Segers2026,
  author = {Segers, Sofie and Langbeen, Jodie and Blot, Stijn and Terryn, Wim and Debrauwere, Mieke and Vogelaers, Dirk},
  title = {Development and validation of a tool for ambulatory monitoring of peripherally inserted central catheter-associated complications},
  journal = {The Journal of Vascular Access},
  year = {2026},
  doi = {10.1177/11297298241305731}
}
Kostenlos starten →