EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparative study between the halfway technique and the standard technique for exchange of tunneled hemodialysis catheter

Adel Kamhawy, AbdelRahman A Nagy iD, Emad M Sallam

The Journal of Vascular Access · 2025

DOI: 10.1177/11297298241286203 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Vascular Access, 2025. Verfasst von Adel Kamhawy und 2 weiteren Autor:innen. Beteiligte Einrichtung: Vascular and Endovascular Surgery Department, Faculty of Medicine, Tanta University, Tanta, Egypt. Hauptthemen laut MEDLINE: Renal Dialysis, Catheterization, Central Venous, Catheters, Indwelling, Central Venous Catheters. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

When indicated, tunneled hemodialysis catheters are usually inserted using the standard technique but, this technique has its complications. The halfway method is performed by exchange of an already-inserted dialysis catheter (tunneled or non-tunneled) to a tunneled one over a guidewire mounted via the old catheter. In this study, we aimed at evaluating the feasibility, safety, and durability of halfway method in comparison to the standard technique (de novo puncture). Patients and methods: This prospective study was conducted during the period from May 2020 till May 2022 and included 87 patients with end-stage renal disease (ESRD) on regular hemodialysis (HD) in need for insertion new tunneled dialysis catheters instead of temporary or malfunctioning tunneled ones. According to the technique of catheter insertion, these patients were divided into two groups: group A (the halfway technique: catheters were exchanged over guidewires under fluoroscopic control; 48 patients) and group B (the standard technique: via de novo ultrasound-guided vein puncture; 39 patients). Instant, delayed complications and 12-months patency rates were reported and analyzed.

Results

The frequency of peri-operative bleeding complications was better in the halfway group with comparable infection rate and late catheter dysfunction results between the two groups. One year patency rates were 87.5% in halfway technique group compared to 79.5% in standard technique group, yet without statistical significance. However, there was a statistically significant shorter operative time in halfway group (15.54 ± 2.6 min vs 26.97 ± 5.6 min, p < 0.001).

Conclusion

The halfway technique may be recommended over the standard technique of tunneled catheter insertion due to shorter operative time, lower rate of hematoma formation, with non-inferior 1-year patency rates and comparable technical success and infection rates. The advantage of access sites preservation for future demand makes this technique of great value to this group of ESRD patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Renal DialysisCatheterization, Central VenousCatheters, IndwellingCentral Venous CathetersKidney Failure, ChronicDevice RemovalHumansMaleProspective StudiesFemaleMiddle AgedTime FactorsAgedTreatment OutcomeFeasibility StudiesVascular PatencyRisk FactorsAdultPuncturesCatheter-Related InfectionsEquipment Design

Stichwörter der Autor:innen

End Stage Renal Diseasehalfway techniquetunneled dialysis catheters

Autor:innen und Institutionen

  • Vascular and Endovascular Surgery Department, Faculty of Medicine, Tanta University, Tanta, Egypt.

ORCID-Profile: AbdelRahman A Nagy

Zitieren

APA

Kamhawy, A., Nagy, A. A., & Sallam, E. M. (2025). Comparative study between the halfway technique and the standard technique for exchange of tunneled hemodialysis catheter. The Journal of Vascular Access. https://doi.org/10.1177/11297298241286203

Vancouver

Kamhawy A, Nagy AA, Sallam EM. Comparative study between the halfway technique and the standard technique for exchange of tunneled hemodialysis catheter. The Journal of Vascular Access. 2025. doi:10.1177/11297298241286203

BibTeX
@article{Kamhawy2025,
  author = {Kamhawy, Adel and Nagy, AbdelRahman A and Sallam, Emad M},
  title = {Comparative study between the halfway technique and the standard technique for exchange of tunneled hemodialysis catheter},
  journal = {The Journal of Vascular Access},
  year = {2025},
  doi = {10.1177/11297298241286203}
}
Kostenlos starten →