EUVIMEDEUVIMED entdecken
Systematische ÜbersichtNetzwerk-Metaanalyse

The efficacy of technology-based devices on the first-attempt success rate for difficult intravenous access in pediatrics: A systematic review and network meta-analysis

Seyed Javad Hosseini iD, Mahbobeh Firooz, Khadijeh Yazdi, Masoud Abdollahi, Seyed Reza Hosseini, Monir Ramezani

The Journal of Vascular Access · 2025-07 · 26 (4) · 1087-1095

DOI: 10.1177/11297298241259843 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift The Journal of Vascular Access, online erschienen am 17.06.2024. Verfasst von Seyed Javad Hosseini und 5 weiteren Autor:innen. Beteiligte Einrichtung: Nursing Department, Esfarayen Faculty of Medical Sciences, Esfarayen, Iran. Hauptthemen laut MEDLINE: Catheterization, Peripheral, Ultrasonography, Interventional, Vascular Access Devices. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 39 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Previous studies have compared various technology-based devices, such as ultrasonography (USG), near-infrared (NIR), and transilluminator (TI), with standard care (SC) to facilitate peripheral intravenous cannulation (PIVC) in pediatric patients. This study aims to investigate the efficacy of these interventions on the first-attempt success rate (FASR) of PIVC in pediatric patients with difficult intravenous access (DIVA) using network meta-analysis (NMA).

Methods

We conducted a comprehensive literature search in databases to identify randomized clinical trials comparing the effects of different devices on the FASR of PIVC from inception until August 2023. Pooled relative risks with 95% credible intervals were estimated using pairwise and network meta-analysis with random effects. To rank the efficacy of devices, we calculated the probabilities of the surface under the cumulative ranking curve (SUCRA).

Results

A total of 18 studies were included in the final analysis. The results of pairwise meta-analysis showed that the use of devices increased the FASR for PIVC by 13% (RR: 1.13, 95% CI: [0.98, 1.30]) compared to SC. The ranking of interventions based on efficacy from highest to lowest was as follows: USG (SUCRA: 1), NIR (SUCRA: 0.6), SC (SUCRA: 0.3), and TI (SUCRA: 0.1), with a very low confidence estimate.

Conclusion

Based on our findings, the prioritization of device usage to increase the FASR of PIVC in pediatric patients with DIVA is as follows: USG, NIR, SC, and TI, respectively. However, due to inconsistencies in the network, existence of an overall high risk of bias in the included studies, and very low confidence estimate, further clinical trials are required.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheterization, PeripheralUltrasonography, InterventionalVascular Access DevicesAdolescentChildChild, PreschoolFemaleHumansInfantMaleAge FactorsEquipment DesignPuncturesRandomized Controlled Trials as TopicRisk FactorsTreatment Outcome

Stichwörter der Autor:innen

Cannulationdifficult intravenous accessnear infraredpediatricperipheral cathetertransilluminatorultrasonography

Autor:innen und Institutionen

  • Nursing Department, Esfarayen Faculty of Medical Sciences, Esfarayen, Iran.
  • Department of Medical Surgical Nursing, School of Nursing and Midwifery, Golestan University of Medical Sciences, Gorgan, Iran.
  • Department of Medical-Surgical Nursing, School of Nursing and Midwifery, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Department of Emergency Nursing, School of Nursing and Midwifery, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Nursing and Midwifery Care Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

ORCID-Profile: Seyed Javad Hosseini

Zitieren

APA

Hosseini, S. J., Firooz, M., Yazdi, K., Abdollahi, M., Hosseini, S. R., & Ramezani, M. (2025). The efficacy of technology-based devices on the first-attempt success rate for difficult intravenous access in pediatrics: A systematic review and network meta-analysis. The Journal of Vascular Access, 26(4), 1087-1095. https://doi.org/10.1177/11297298241259843

Vancouver

Hosseini SJ, Firooz M, Yazdi K, Abdollahi M, Hosseini SR, Ramezani M. The efficacy of technology-based devices on the first-attempt success rate for difficult intravenous access in pediatrics: A systematic review and network meta-analysis. The Journal of Vascular Access. 2025;26(4):1087-1095. doi:10.1177/11297298241259843

BibTeX
@article{Hosseini2025,
  author = {Hosseini, Seyed Javad and Firooz, Mahbobeh and Yazdi, Khadijeh and Abdollahi, Masoud and Hosseini, Seyed Reza and Ramezani, Monir},
  title = {The efficacy of technology-based devices on the first-attempt success rate for difficult intravenous access in pediatrics: A systematic review and network meta-analysis},
  journal = {The Journal of Vascular Access},
  year = {2025},
  volume = {26},
  number = {4},
  pages = {1087--1095},
  doi = {10.1177/11297298241259843}
}
Kostenlos starten →