EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Efficacy of drug-coated balloon catheters for patients with short-term recurrent dysfunction of arteriovenous fistula

Sadanori Shintaku iD, Hideki Kawanishi, Masataka Banshodani iD, Misaki Moriishi, Naoko Takahashi, Shinichiro Tsuchiya

The Journal of Vascular Access · 2025

DOI: 10.1177/11297298241245853 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift The Journal of Vascular Access, 2025. Verfasst von Sadanori Shintaku und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Kidney Disease and Blood Purification Therapy, Tsuchiya General Hospital, Hiroshima, Japan. Hauptthemen laut MEDLINE: Arteriovenous Shunt, Surgical, Angioplasty, Balloon, Graft Occlusion, Vascular, Renal Dialysis. Die Arbeit nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In this study, we aimed at clarifying the usefulness of drug-coated balloon catheters (DCBs) for arteriovenous fistulas (AVFs) that repeatedly undergo restenosis over a short period and to examine the factors that influence the patency period after DCB use.

Methods

This retrospective observational study was conducted using IN.PACT AV in 29 cases of AVFs with repeated restenosis within approximately 3 months, and temporary patency before and after DCB use in the same patients was compared. For target participants, the flow volume, resistive index (RI), and vascular diameter of the brachial artery were measured using an ultrasound diagnostic device. Stenosis diameter, reference vessel diameter, and stenosis length of the lesion were measured before and after DCB dilatation using digital subtraction angiography.

Results

Before DCB angioplasty, the postintervention primary patency at 3 months was 66%, and the average interval was 92 ± 21 days (mean ± standard deviation). After DCB angioplasty, the postintervention primary patency rates at 3 and 6 months were 92% and 36%, respectively. The postintervention primary patency was significantly higher after than before DCB angioplasty ( p < 0.0001). A sub-analysis was performed on 25 patients who were followed up for 4 months or more after DCB. The RI values before and after dilatation with DCB significantly differed between the patency group 4 or more months after DCB and the patency group less than 4 months after DCB.

Conclusion

For AVFs that require frequent PTA over a short period of time, DCB improved the patency rate 3 months after PTA, but the improvement effect at 6 months was limited. The effect of DCB on prolonging the patency rate of AVFs that require frequent PTA over a short period of time may be correlated with the RI value before and after PTA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arteriovenous Shunt, SurgicalAngioplasty, BalloonGraft Occlusion, VascularRenal DialysisCoated Materials, BiocompatibleVascular Access DevicesCardiovascular AgentsHumansVascular PatencyRetrospective StudiesMaleFemaleTime FactorsTreatment OutcomeRecurrenceMiddle AgedAgedEquipment DesignRisk FactorsRegional Blood FlowAngiography, Digital Subtraction

Stichwörter der Autor:innen

Drug-coated balloonarteriovenous fistulahemodialysispercutaneous transluminal angioplastyresistive indexultrasound

Substanzen

Coated Materials, BiocompatibleCardiovascular Agents

Autor:innen und Institutionen

  • Department of Kidney Disease and Blood Purification Therapy, Tsuchiya General Hospital, Hiroshima, Japan.
  • Nakajima Tsuchiya Clinic, Hiroshima, Japan.
  • Omachi Tsuchiya Clinic, Hiroshima, Japan.

ORCID-Profile: Sadanori Shintaku, Masataka Banshodani

Zitieren

APA

Shintaku, S., Kawanishi, H., Banshodani, M., Moriishi, M., Takahashi, N., & Tsuchiya, S. (2025). Efficacy of drug-coated balloon catheters for patients with short-term recurrent dysfunction of arteriovenous fistula. The Journal of Vascular Access. https://doi.org/10.1177/11297298241245853

Vancouver

Shintaku S, Kawanishi H, Banshodani M, Moriishi M, Takahashi N, Tsuchiya S. Efficacy of drug-coated balloon catheters for patients with short-term recurrent dysfunction of arteriovenous fistula. The Journal of Vascular Access. 2025. doi:10.1177/11297298241245853

BibTeX
@article{Shintaku2025,
  author = {Shintaku, Sadanori and Kawanishi, Hideki and Banshodani, Masataka and Moriishi, Misaki and Takahashi, Naoko and Tsuchiya, Shinichiro},
  title = {Efficacy of drug-coated balloon catheters for patients with short-term recurrent dysfunction of arteriovenous fistula},
  journal = {The Journal of Vascular Access},
  year = {2025},
  doi = {10.1177/11297298241245853}
}
Kostenlos starten →