EUVIMEDEUVIMED entdecken
Crossref

A modified single-catheter approach for improving adrenal venous sampling in patients with primary aldosteronism

Jindong Wan, Xinquan Wang, Sen Liu, Jixin Hou, Peng Zhou, Qiang Xue, Peijian Wang iD

The Journal of Vascular Access · 2025

DOI: 10.1177/11297298231213669 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Vascular Access, 2025. Verfasst von Jindong Wan und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, The First Affiliated Hospital of Chengdu Medical College, Chengdu, Sichuan, PR China. Hauptthemen laut MEDLINE: Hyperaldosteronism, Adrenal Glands, Catheterization, Peripheral, Aldosterone. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Adrenal vein sampling (AVS) is an established procedure for assessing subtype patients with primary aldosteronism (PA). However, it is technically challenging, with high failure rates, which limits its application in clinical practice. Our study aimed to evaluate the safety and efficacy of a single-catheter modified approach for AVS.

Methods

The clinical, angiographic, and procedural data of 182 consecutive patients who underwent AVS procedures between May 2020 and May 2023 were collected and analyzed. The single-catheter modified approach was performed as a single 5 F Tiger catheter with only one-time manual reshaping, which was recommended for sequential bilateral adrenal cannulations.

Results

Of the 182 consecutive patients, 174 (95.6%) had successful bilateral adrenal cannulation. The single-catheter modified approach was successfully performed to cannulate the right adrenal vein in 176 (96.7%) patients, while another six (3.3%) patients needed at least a second manual reshaping for 5 F Tiger catheters. For left adrenal cannulation, a single-catheter modified approach was successfully used in 179 (98.4%) patients, whereas 5 F Tiger catheters with at least second-time manual reshaping were used in the remaining three (1.6%) patients. The procedural period was 15.6 ± 10.8 min, the fluoroscopy time was 4.2 ± 1.5 min, and the diagnostic contrast was 15.5 ± 4.8 mL. The incidence of procedure-related complications associated with AVS was 1.1%. The cumulative summation assessment illustrated that the learning curve for the operating procedure required up to 29 cases, indicating that the procedure time was shortened after 29 cases.

Conclusions

The single-catheter modified approach is an effective, safe, and feasible technique for AVS treatment. In particular, this improved method is not difficult for beginners with high technical success rates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HyperaldosteronismAdrenal GlandsCatheterization, PeripheralAldosteroneVeinsVascular Access DevicesHumansFemaleMaleMiddle AgedAdultRetrospective StudiesAgedPredictive Value of TestsEquipment DesignTime FactorsBiomarkers

Stichwörter der Autor:innen

Adrenal venous samplingTiger catheterefficacyhyperaldosteronismsafety

Substanzen

AldosteroneBiomarkers

Autor:innen und Institutionen

  • Department of Cardiology, The First Affiliated Hospital of Chengdu Medical College, Chengdu, Sichuan, PR China.
  • Sichuan Clinical Research Center for Geriatrics, The First Affiliated Hospital of Chengdu Medical College, Chengdu, Sichuan, PR China.
  • Key Laboratory of Aging and Vascular Homeostasis of Sichuan Higher Education Institutes, Chengdu, Sichuan, PR China.
  • Department of Cardiology, Yan'an Affiliated Hospital of Kunming Medical University, Kunming, Yunnan, PR China.

ORCID-Profile: Peijian Wang

Zitieren

APA

Wan, J., Wang, X., Liu, S., Hou, J., Zhou, P., Xue, Q., & Wang, P. (2025). A modified single-catheter approach for improving adrenal venous sampling in patients with primary aldosteronism. The Journal of Vascular Access. https://doi.org/10.1177/11297298231213669

Vancouver

Wan J, Wang X, Liu S, Hou J, Zhou P, Xue Q, et al. A modified single-catheter approach for improving adrenal venous sampling in patients with primary aldosteronism. The Journal of Vascular Access. 2025. doi:10.1177/11297298231213669

BibTeX
@article{Wan2025,
  author = {Wan, Jindong and Wang, Xinquan and Liu, Sen and Hou, Jixin and Zhou, Peng and Xue, Qiang and Wang, Peijian},
  title = {A modified single-catheter approach for improving adrenal venous sampling in patients with primary aldosteronism},
  journal = {The Journal of Vascular Access},
  year = {2025},
  doi = {10.1177/11297298231213669}
}
Kostenlos starten →