EUVIMEDEUVIMED entdecken
Crossref

Analysis of tip malposition and correction of peripherally inserted central catheters under ultrasound-guidance: 5-year outcomes from a single center

Eunju Jang iD, Soo Mi Son, Ki-Yoon Moon, Seunghoon Lee, Hong Seok Han, Sun Cheol Park, Jang Yong Kim, Sang Seob Yun iD

The Journal of Vascular Access · 2025

DOI: 10.1177/11297298231209564 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Vascular Access, 2025. Verfasst von Eunju Jang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Vascular and Transplant Surgery, Department of Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea,…. Hauptthemen laut MEDLINE: Catheterization, Peripheral, Catheterization, Central Venous, Ultrasonography, Interventional, Central Venous Catheters. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Peripherally inserted central catheter (PICC) has become a common procedure. Although ultrasound (US)-guidance has improved success rates, a small percentage of malposition is inevitable. The purpose of our study is to evaluate malposition rates of US-guided bedside PICC catheter insertion, and the clinical factors associated with malposition.

Methods

This is a retrospective cohort study evaluating 5981 patients who had undergone ultrasound-guided bedside PICC placement from January 2017 to December 2021 at a single tertiary center. Final tip location was confirmed on chest radiograph.

Results

Patients were categorized into optimal, suboptimal, and malposition groups according to final tip location. 4866 cases (81.7%) showed optimal tip position, 790 (13.3%) were suboptimal, and 299 (5.0%) were malpositioned. Logistic regression analysis identified six variables associated with tip malposition; height (odds ratio (OR) 1.044; 95% confidence interval (CI), 1.028–1.061; p < 0.001), body mass index (BMI) (OR 1.051; 95% CI, 1.017–1.087; p = 0.003), prior failure at accessing peripheral intravenous (IV) access (OR 1.718; 95% CI, 1.215–2.428; p = 0.002), side of the arm (OR 3.467; 95% CI, 2.457–4.891; p < 0.001), length of the catheter (OR 0.763; 95% CI, 0.734–0.794; p < 0.001), and number of previous central catheter insertions (OR 1.069; 95% CI, 1.004–1.140; p = 0.038). Malpositioned catheters were corrected by either bedside repositioning, bedside reinsertion, fluoroscopic reinsertion, switching to jugular catheters or catheter removal. No patient related factors were significantly associated with malposition or success of reposition.

Conclusion

US-guidance can help reduce catheter malposition during bedside PICC insertion. Patients with risk factors such as multiple previous central vein insertions, failed peripheral line insertions, left arm insertion, or high BMI should undergo thorough sonographic evaluation of the arm vessels to prevent malposition.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheterization, PeripheralCatheterization, Central VenousUltrasonography, InterventionalCentral Venous CathetersCatheters, IndwellingHumansRetrospective StudiesFemaleMaleMiddle AgedRisk FactorsAgedTime FactorsTreatment OutcomeAdultRisk AssessmentAged, 80 and over

Stichwörter der Autor:innen

Peripherally inserted central catheter line insertionultrasonographyvascular access devices

Autor:innen und Institutionen

  • Division of Vascular and Transplant Surgery, Department of Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seocho-gu, Seoul, Republic of Korea.

ORCID-Profile: Eunju Jang, Sang Seob Yun

Zitieren

APA

Jang, E., Son, S. M., Moon, K. Y., Lee, S., Han, H. S., Park, S. C., Kim, J. Y., & Yun, S. S. (2025). Analysis of tip malposition and correction of peripherally inserted central catheters under ultrasound-guidance: 5-year outcomes from a single center. The Journal of Vascular Access. https://doi.org/10.1177/11297298231209564

Vancouver

Jang E, Son SM, Moon KY, Lee S, Han HS, Park SC, et al. Analysis of tip malposition and correction of peripherally inserted central catheters under ultrasound-guidance: 5-year outcomes from a single center. The Journal of Vascular Access. 2025. doi:10.1177/11297298231209564

BibTeX
@article{Jang2025,
  author = {Jang, Eunju and Son, Soo Mi and Moon, Ki-Yoon and Lee, Seunghoon and Han, Hong Seok and Park, Sun Cheol and Kim, Jang Yong and Yun, Sang Seob},
  title = {Analysis of tip malposition and correction of peripherally inserted central catheters under ultrasound-guidance: 5-year outcomes from a single center},
  journal = {The Journal of Vascular Access},
  year = {2025},
  doi = {10.1177/11297298231209564}
}
Kostenlos starten →