Comparison of the complications and long-term results of heparin-coated and non-heparin-coated symmetric-tip hemodialysis catheters
The Journal of Vascular Access · 2025
DOI: 10.1177/11297298231202536 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Vascular Access, 2025. Verfasst von Mustafa Özdemir und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Sakarya University Faculty of Medicine, Sakarya, Turkey. Hauptthemen laut MEDLINE: Heparin, Renal Dialysis, Coated Materials, Biocompatible, Catheters, Indwelling. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 10 Literaturangaben.
Abstract (Originalsprache)
Background
Tunneled catheters are effectively used in patients receiving chronic dialysis due to end-stage renal disease. However, the dysfunction of catheters caused by infection or thrombus requires repetitive procedures. In this study, we aimed to compare the long-term results of heparin-coated and non-heparin-coated tunneled dialysis catheters.
Method
The study included a total of 161 patients who underwent tunneled dialysis catheter placement. Heparin-coated and non-heparin-coated tunneled catheters were placed in 81 and 80 patients, respectively. Of all the patients, 89 (55.3%) were male and 72 (44.7%) were female. The mean age of the patients was 64.3 ± 15.3 years. The patients were followed up for 12 months.
Results
Catheter infection developed in 10 (6.2%) of the cases, of which seven (70%) resolved with antibiotic therapy and the remaining three (30%) required catheter replacement. There was no significant difference between the groups in terms of the catheter infection rate ( p = 0.84). Fibrin sheaths developed in nine (5.5%) patients. Fibrin sheath development was found to be significantly higher in the non-heparin-coated catheters ( p = 0.017). There was no significant difference in fibrin sheath formation between the patients with and without systemic antiaggregant use ( p = 0.864). The mean catheter durability time was determined to be 11 months in both groups ( p = 0.704). Catheter survival was similar in heparin-coated and non-heparin coated catheters.
Conclusion
This study showed that the rate of fibrin sheath development was significantly lower in heparin-coated tunneled catheters than non-heparin-coated catheters. There was no significant difference between the two catheters in terms of the rates of infection and mechanical complications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Sakarya University Faculty of Medicine, Sakarya, Turkey.
ORCID-Profile: Mustafa Özdemir, Onur Taydaş
Zitieren
APA
Özdemir, M., Taydaş, O., Danışan, G., & Ateş, Ö. F. (2025). Comparison of the complications and long-term results of heparin-coated and non-heparin-coated symmetric-tip hemodialysis catheters. The Journal of Vascular Access. https://doi.org/10.1177/11297298231202536
Vancouver
Özdemir M, Taydaş O, Danışan G, Ateş ÖF. Comparison of the complications and long-term results of heparin-coated and non-heparin-coated symmetric-tip hemodialysis catheters. The Journal of Vascular Access. 2025. doi:10.1177/11297298231202536
BibTeX
@article{zdemir2025,
author = {Özdemir, Mustafa and Taydaş, Onur and Danışan, Gürkan and Ateş, Ömer Faruk},
title = {Comparison of the complications and long-term results of heparin-coated and non-heparin-coated symmetric-tip hemodialysis catheters},
journal = {The Journal of Vascular Access},
year = {2025},
doi = {10.1177/11297298231202536}
}
EUVIMED