Comparison of complications and indwelling time of midline catheter at different tip locations: A systematic review and meta-analysis
The Journal of Vascular Access · 2024
DOI: 10.1177/11297298231199776 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Vascular Access, 2024. Verfasst von Huixin Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nursing, Beijing Tiantan Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Catheter Obstruction, Catheterization, Central Venous, Catheters, Indwelling, Central Venous Catheters. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: beijing tian tan hospital, capital medical university, capital health research and development of special fund, “Green Seedling” talent project of Beijing Medical Management Center.
Abstract (Originalsprache)
This review was performed to determine whether different tip locations of a midline catheter can cause differences in the incidence of complications and the catheter indwelling time. PubMed, Embase, Web of Science, the Cochrane Library, Cumulative Index to Nursing and Allied Health Literature (CINAHL), China National Knowledge Infrastructure (CNKI), and Wanfang were systematically searched. RevMan 5.3 software was used for the meta-analysis. Heterogeneity was evaluated, and the mean differences or odds ratios with 95% confidence intervals were calculated. Eight studies met the inclusion criteria. The meta-analysis showed statistically significant differences in the complication rates (OR = 0.53; 95% CI = 0.34–0.84; p = 0.006) and incidence of catheter-related thrombosis (OR = 0.29; 95% CI = 0.11–0.76; p = 0.01) between midline catheter tip positioning in the subclavian vein and axillary vein. There were no significant differences in the catheter indwelling time or other complications such as phlebitis, catheter-related occlusion, catheter-related infiltration, pain, and catheter dislodgement between midline catheter tip positioning in the subclavian vein and axillary vein. There were statistically significant differences in the complication rates (OR = 0.23; 95% CI = 0.36–0.57; p < 0.001), incidence of catheter-related occlusion (OR = 0.29; 95% CI = 0.10–0.83; p = 0.02), and incidence of catheter-related infiltration (OR = 0.33; 95% CI = 0.17–0.63; p < 0.001) between midline catheter tip positioning in the proximal and distal axillary vein. Placement of the midline catheter tip in the subclavian vein was superior to that in the axillary vein in terms of complication rates and the incidence of catheter-related thrombosis. Whether different midline catheter tip locations lead to differences in the catheter indwelling time or the rates of other complications remains unclear. More high-quality studies incorporating relevant outcomes are needed for confirmation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Nursing, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
- Department of International Medical Service, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
ORCID-Profile: Huixin Zhang
Förderung
- beijing tian tan hospital, capital medical university
- capital health research and development of special fund
- “Green Seedling” talent project of Beijing Medical Management Center
Zitieren
APA
Zhang, H., Li, X., Sun, W., Zhang, R., & Cai, W. (2024). Comparison of complications and indwelling time of midline catheter at different tip locations: A systematic review and meta-analysis. The Journal of Vascular Access. https://doi.org/10.1177/11297298231199776
Vancouver
Zhang H, Li X, Sun W, Zhang R, Cai W. Comparison of complications and indwelling time of midline catheter at different tip locations: A systematic review and meta-analysis. The Journal of Vascular Access. 2024. doi:10.1177/11297298231199776
BibTeX
@article{Zhang2024,
author = {Zhang, Huixin and Li, Xin and Sun, Weige and Zhang, Ran and Cai, Weixin},
title = {Comparison of complications and indwelling time of midline catheter at different tip locations: A systematic review and meta-analysis},
journal = {The Journal of Vascular Access},
year = {2024},
doi = {10.1177/11297298231199776}
}
EUVIMED