Use of a novel tapered, scoring balloon to treat juxta-anastomotic stenosis in AV fistula
The Journal of Vascular Access · 2024
DOI: 10.1177/11297298231195730 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Vascular Access, 2024. Verfasst von Xiangjie Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular Surgery, the First Affiliated Hospital of Chongqing Medical University, Chongqing, China. Hauptthemen laut MEDLINE: Arteriovenous Shunt, Surgical, Vascular Patency, Angioplasty, Balloon, Graft Occlusion, Vascular. Die Arbeit nennt 4 Literaturangaben. Gefördert von: Chongqing Science and Technology Bureau and Health Commission joint medical research project.
Abstract (Originalsprache)
Background
Juxta-anastomotic stenosis, the most common lesion in arteriovenous fistula, creates a dilemma for optimal balloon size choosing during PTA.
Objectives
To descript the effect of a novel tapered scoring balloon catheter (DK Medtech, Suzhou, China) which has a conical shape with an increasing diameter from the front part of the balloon to the end, and three non-slip elements attached on the surface of the balloon. Research design: Case series of 10 patients used this balloon catheter was retrospectively analyzed. Subjects: Patients with juxta-anastomotic stenosis. Measures: A retrospective review of 10 cases using the novel tapered, scoring balloon catheter in our center was performed.
Results
All cases were clinical technique success. The average total procedure time was 16.7 min with 2:14 of fluoroscopy time. No complications such as vascular rupture or dissection occurred. The primary patency rates at 6 and 12 month were 80% and 50% separately.
Conclusions
This tapered scoring balloon provides an economical, safe, and efficient management for juxta-anastomotic stenosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Vascular Surgery, the First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
ORCID-Profile: Xiangjie Li, Zhe Wang, Qining Fu
Förderung
- Chongqing Science and Technology Bureau and Health Commission joint medical research project
Zitieren
APA
Li, X., Wang, Z., Zhao, X., Sun, H., & Fu, Q. (2024). Use of a novel tapered, scoring balloon to treat juxta-anastomotic stenosis in AV fistula. The Journal of Vascular Access. https://doi.org/10.1177/11297298231195730
Vancouver
Li X, Wang Z, Zhao X, Sun H, Fu Q. Use of a novel tapered, scoring balloon to treat juxta-anastomotic stenosis in AV fistula. The Journal of Vascular Access. 2024. doi:10.1177/11297298231195730