Fachartikel in der Zeitschrift The Journal of Vascular Access, 2024. Verfasst von Carmen Rodriguez Perez und 2 weiteren Autor:innen. Beteiligte Einrichtung: Neonatal Intensive Care Unit, Children's Hospital, ASST Spedali Civili, Brescia, Italy. Hauptthemen laut MEDLINE: Catheterization, Central Venous, Central Venous Catheters, Catheters, Indwelling, Ultrasonography, Interventional. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Chest-to-arm (CTA) tunneling technique has been described recently as an alternative option to exit site of the catheter in the infraclavicular area.

Method

We report our experience with ultrasound-guided centrally inserted central catheters (CICCs) placed using CTA tunneling in six neonates. All central venous catheters were positioned with ultrasound guidance and real-time tip location.

Results

There were no insertion-related complications; all devices were correctly positioned at the first attempt. During the follow-up, we found no catheter-related thrombosis, infections, or catheter malfunction. No tip position-related complications. Only one case of secondary malposition was reported.

Conclusion

In our experience, the CTA tunneling technique is reliable, safe, and feasible in the neonate even from the first hours of life, as well as for preterm newborns; it could be a valid alternative to the usual exit site.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheterization, Central VenousCentral Venous CathetersCatheters, IndwellingUltrasonography, InterventionalHumansInfant, NewbornTreatment OutcomeUpper ExtremityMaleFemale

Stichwörter der Autor:innen

Neonatecentral venous cathetercentrally inserted central catheterchest-to-arm tunnelingcritically illneonatal intensive care unitnewborntunneled cathetersultrasound

Autor:innen und Institutionen

  • Neonatal Intensive Care Unit, Children's Hospital, ASST Spedali Civili, Brescia, Italy.

ORCID-Profile: Carmen Rodriguez Perez

Zitieren

APA

Rodriguez Perez, C., Pezzotti, E., & Risso, F. M. (2024). Chest-to-arm tunneling technique for central venous access devices in neonates. The Journal of Vascular Access. https://doi.org/10.1177/11297298231174064

Vancouver

Rodriguez Perez C, Pezzotti E, Risso FM. Chest-to-arm tunneling technique for central venous access devices in neonates. The Journal of Vascular Access. 2024. doi:10.1177/11297298231174064

BibTeX
@article{RodriguezPerez2024,
  author = {Rodriguez Perez, Carmen and Pezzotti, Elena and Risso, Francesco Maria},
  title = {Chest-to-arm tunneling technique for central venous access devices in neonates},
  journal = {The Journal of Vascular Access},
  year = {2024},
  doi = {10.1177/11297298231174064}
}
Kostenlos starten →