Vergleichsstudie in der Zeitschrift The Journal of Vascular Access, 2024. Verfasst von Rodney J Lane und 2 weiteren Autor:innen. Beteiligte Einrichtung: Royal North Shore Hospital, St Leonards, NSW, Australia. Hauptthemen laut MEDLINE: Amputation, Surgical, Antineoplastic Agents. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NSW Health.
Themen: Onkologische Pflege
Abstract (Originalsprache)
Background
Vascular access via a single arterial catheter for targeted chemotherapy delivery has difficulties with concentration, dilution, drug retention, plasma binding, and lack of control of the tumour microcirculation. An implantable arterial access system to accommodate multi-catheter access was developed address these problems. The system was also adapted for isolated arterial-to-arterial extracorporeal suprasystolic perfusion for end stage peripheral vascular disease. The arterial-to-arterial logistics were compared with standard venovenous and arteriovenous fistulae access employed in haemodialysis.
Methods
Targeted chemotherapy delivery was addressed in a pilot study of vascular liver isolation. Ten patients with secondary colorectal cancer, were treated with multiple infusions employing up to five individually steered catheters. The arterial-to-arterial extracorporeal access system was also used to treat end stage peripheral vascular disease in 20 patients where amputation was the only option. The trial was named Hypertensive Extracorporeal Limb Perfusion (HELP).
Results
Multiple day only infusions produced a partial response or stable disease in six out of the ten patients in an ‘end stage’ setting. The mean survival was 11.2 months. Of the twenty patients facing amputation 40% had avoided amputation at follow-up 22 months and 20% had delay of 4 months.
Conclusion
The access system allows repeatable steerable multi-catheter arterial access for chemotherapy delivery to address difficulties of concentration, dilution, plasma binding and microvascular control. The access system supports multiple repeatable suprasystolic extracorporeal arterial to arterial access. It is cardiac independent generating flows of greater than 1 L/min with zero flow in between treatments. The device logistics compares favourably with arteriovenous and venovenous access systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Royal North Shore Hospital, St Leonards, NSW, Australia.
- North Shore Private Hospital, St Leonards, NSW, Australia.
- Macquarie University Hospital, Macquarie Park, NSW, Australia.
- AllVascular Pty Ltd, St Leonards, NSW, Australia.
- School of Biomedical Engineering, University of Sydney, Sydney, NSW, Australia.
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW, Australia.
ORCID-Profile: Rodney J Lane
Förderung
- NSW Health
Zitieren
APA
Lane, R. J., Keogh, S. E., & Khin, N. Y. (2024). An arterial access system for targeted chemotherapy delivery and arterial-arterial extracorporeal recirculation for ‘end stage’ peripheral vascular disease. The Journal of Vascular Access. https://doi.org/10.1177/11297298231165642
Vancouver
Lane RJ, Keogh SE, Khin NY. An arterial access system for targeted chemotherapy delivery and arterial-arterial extracorporeal recirculation for ‘end stage’ peripheral vascular disease. The Journal of Vascular Access. 2024. doi:10.1177/11297298231165642
BibTeX
@article{Lane2024,
author = {Lane, Rodney J and Keogh, Sarah E and Khin, Nyan Y},
title = {An arterial access system for targeted chemotherapy delivery and arterial-arterial extracorporeal recirculation for ‘end stage’ peripheral vascular disease},
journal = {The Journal of Vascular Access},
year = {2024},
doi = {10.1177/11297298231165642}
}
EUVIMED