The impact of hip geometrical parameters on muscle and joint biomechanics during normal gait
HIP International · 2026
DOI: 10.1177/11207000261447780 ↗Kurz gefasst
Fachartikel in der Zeitschrift HIP International, 2026. Verfasst von Mahdie Aghasizade und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, University of Tehran, Tehran, Iran. Hauptthemen laut MEDLINE: Gait, Hip Joint, Muscle, Skeletal, Arthroplasty, Replacement, Hip. Die Arbeit nennt 16 Literaturangaben.
Abstract (Originalsprache)
Background
Effective preoperative planning is essential for reducing pain, fatigue, and joint damage following total hip arthroplasty (THA). This study investigates the effects of key geometric parameters – neck-shaft angle (NSA), anteversion angle (AVA), and hip offset (HO) – on muscle mechanics and joint reaction forces during normal walking gait using musculoskeletal simulation.
Methods
A MATLAB-based HO tool combined with a femoral torsion tool was used to generate 45 OpenSim models with systematic variations in NSA, AVA, and HO. All models were evaluated using identical gait kinematics and ground reaction forces to isolate the biomechanical influence of geometric changes.
Results
Increases in femoral neck length and HO substantially affect muscle lever arms and joint reaction forces, with peak hip and knee joint loading and associated muscle mechanics increasing by up to approximately 2.5-fold compared to the reference model. Changes in NSA, AVA, and HO significantly altered muscle moment arms, muscle activations, and muscle forces, particularly in hip abductors and flexors. Simultaneous variation of all 3 parameters produced markedly larger effects than isolated changes.
Conclusions
This study highlights the importance of considering prosthesis geometry and implantation parameters during THA planning and biomechanical modelling to optimise gait mechanics and reduce postoperative joint loading.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Mechanical Engineering, University of Tehran, Tehran, Iran.
ORCID-Profile: Mahdie Aghasizade
Zitieren
APA
Aghasizade, M., Karimpour, M., Shariat Panahi, M., Rostamian, R., & Kashani, H. G. (2026). The impact of hip geometrical parameters on muscle and joint biomechanics during normal gait. HIP International. https://doi.org/10.1177/11207000261447780
Vancouver
Aghasizade M, Karimpour M, Shariat Panahi M, Rostamian R, Kashani HG. The impact of hip geometrical parameters on muscle and joint biomechanics during normal gait. HIP International. 2026. doi:10.1177/11207000261447780
BibTeX
@article{Aghasizade2026,
author = {Aghasizade, Mahdie and Karimpour, Morad and Shariat Panahi, Masoud and Rostamian, Reyhane and Kashani, Hadi G},
title = {The impact of hip geometrical parameters on muscle and joint biomechanics during normal gait},
journal = {HIP International},
year = {2026},
doi = {10.1177/11207000261447780}
}
EUVIMED