EUVIMEDEUVIMED entdecken
Crossref

Acoustic evaluation by artificial intelligence for initial press-fit cementless cup fixation in total hip arthroplasty

Yasuhiro Homma iD, Ken Tashiro iD, Hiroshi Ohtsu, Koju Hayashi, Taiji Watari, Tomonori Baba iD, Muneaki Ishijima

HIP International · 2026-07 · 36 (4) · 536-540

DOI: 10.1177/11207000261429419 ↗

Kurz gefasst

Fachartikel in der Zeitschrift HIP International, online erschienen am 22.07.2026. Verfasst von Yasuhiro Homma und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Tokyo, Japan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Artificial Intelligence, Osteoarthritis, Hip. Die Arbeit nennt 20 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science, the Japanese Society for Replacement Arthroplasty Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

This study aimed to assess the evaluation accuracy of an artificial intelligence (AI) algorithm using the hammering sound to assess initial press-fit fixation in cementless total hip arthroplasty (THA). The acoustic features of the hammering sounds during a press-fit cup fixation were recorded and analysed.

Methods

81 hips of 79 patients undergoing primary THA using the Trident HA acetabular system (Stryker, Kalamazoo, MI, USA) for treatment of osteoarthritis and osteonecrosis of the femoral head were included. After the fast Fourier transform analysis was performed on the hammering sound, 24 sound pressure (SP) features across 23 frequency bands were extracted and applied to binary classification. Support vector machine algorithms were used to classify the data using 2 models: Model A - SP only; Model B - SP + patient characteristics.

Results

Among the 81 hips in 79 patients, the hammering sound of 348 impacts of 70 successful press-fit of 1 st attempts in 70 hips and 80 impacts of 16 failed attempts in 11hips were analysed. The area under the curve for the test data was 0.9554 in Model A and 1.0 in Model B. The accuracy (accuracy/sensitivity/specificity/positive predictive value/negative predictive value) of each model in the test data was as follows: Model A, 0.849/1.000/0.188/0.843/1.000 and Model B, 0.965/1.000/0.813/0.959/1.000.

Conclusions

The accuracy of an AI algorithm using hammering sounds to judge the success of initial press-fit fixation in cementless cup in THA was relatively high. Our results imply the possibility of a practical application for such a system to assist surgeons during the procedure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisArtificial IntelligenceOsteoarthritis, HipAcousticsProsthesis FittingFemur Head NecrosisHumansFemaleMaleAgedMiddle AgedProsthesis DesignAlgorithms

Stichwörter der Autor:innen

Artificial intelligencehammering sound analysispress-fit fixationtotal hip arthroplasty

Autor:innen und Institutionen

  • Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Tokyo, Japan.
  • Department of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, Japan.
  • Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Ibaraki, Japan.
  • Medical Technology Innovation Centre, Juntendo University, Tokyo, Japan.

ORCID-Profile: Yasuhiro Homma, Ken Tashiro, Tomonori Baba

Förderung

  • Japan Society for the Promotion of Science
  • the Japanese Society for Replacement Arthroplasty Foundation

Zitieren

APA

Homma, Y., Tashiro, K., Ohtsu, H., Hayashi, K., Watari, T., Baba, T., & Ishijima, M. (2026). Acoustic evaluation by artificial intelligence for initial press-fit cementless cup fixation in total hip arthroplasty. HIP International, 36(4), 536-540. https://doi.org/10.1177/11207000261429419

Vancouver

Homma Y, Tashiro K, Ohtsu H, Hayashi K, Watari T, Baba T, et al. Acoustic evaluation by artificial intelligence for initial press-fit cementless cup fixation in total hip arthroplasty. HIP International. 2026;36(4):536-540. doi:10.1177/11207000261429419

BibTeX
@article{Homma2026,
  author = {Homma, Yasuhiro and Tashiro, Ken and Ohtsu, Hiroshi and Hayashi, Koju and Watari, Taiji and Baba, Tomonori and Ishijima, Muneaki},
  title = {Acoustic evaluation by artificial intelligence for initial press-fit cementless cup fixation in total hip arthroplasty},
  journal = {HIP International},
  year = {2026},
  volume = {36},
  number = {4},
  pages = {536--540},
  doi = {10.1177/11207000261429419}
}
Kostenlos starten →