EUVIMEDEUVIMED entdecken
Crossref

An algorithm for automated femoral leg length and offset calculations on pelvis radiographs

Kellen L Mulford iD, Ryan D Roman, Joshua R Labott, Elizabeth S Kaji, Austin F Grove, Michael J Taunton, Cody C Wyles iD

HIP International · 2026-05 · 36 (3) · 388-397

DOI: 10.1177/11207000261421918 ↗

Kurz gefasst

Fachartikel in der Zeitschrift HIP International, online erschienen am 05.03.2026. Verfasst von Kellen L Mulford und 6 weiteren Autor:innen. Beteiligte Einrichtung: Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopaedic Surgery, Mayo Clinic, Rochester, MN, USA. Hauptthemen laut MEDLINE: Femur, Arthroplasty, Replacement, Hip, Leg Length Inequality, Radiography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Manual measurement of leg length (LL) and offset can be tedious. This study developed an automated algorithm for measuring LL and offset from pre- and postoperative AP pelvis radiographs in a large cohort of THA patients.

Methods

Using a deep learning model trained on 1100 total AP pelvis radiographs, an algorithm was developed to calculate LL and offset. Algorithm measurements were compared with manual measurements by 4 raters on a sample of 100 pre- and postoperative image pairs. Inter- and intra-rater consistency was calculated using the intraclass correlation coefficient (ICC). The algorithm was applied to calculate the pre- and postoperative LL and offset discrepancies and the change in LL and offset bilaterally in a cohort of 15,951 image pairs.

Results

ICC values between the algorithm and human raters ranged from 0.83 to 0.88 for offset measurements and 0.92 to 0.97 for LL measurements. Human raters demonstrated good-to-excellent inter-rater ICC and uniformly excellent intra-rater ICC. Entire database measurements demonstrated shorter LLs for arthritic joints versus the contralateral leg preoperatively and reduced LL discrepancy post-arthroplasty.

Conclusions

We present a deep learning algorithm for calculating LL and offset using AP pelvis radiographs. This tool can support population-level studies and may assist operative management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FemurArthroplasty, Replacement, HipLeg Length InequalityRadiographyAlgorithmsPelvisDeep LearningRetrospective StudiesPostoperative PeriodPreoperative PeriodImage Processing, Computer-AssistedImage Interpretation, Computer-AssistedHumans

Stichwörter der Autor:innen

Computer visiondeep learningleg lengthoffsetprimary total hip arthroplasty

Autor:innen und Institutionen

  • Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopaedic Surgery, Mayo Clinic, Rochester, MN, USA.
  • Mayo Clinic Department of Orthopaedic Surgery, Mayo Clinic, Rochester, MN, USA.

ORCID-Profile: Kellen L Mulford, Cody C Wyles

Zitieren

APA

Mulford, K. L., Roman, R. D., Labott, J. R., Kaji, E. S., Grove, A. F., Taunton, M. J., & Wyles, C. C. (2026). An algorithm for automated femoral leg length and offset calculations on pelvis radiographs. HIP International, 36(3), 388-397. https://doi.org/10.1177/11207000261421918

Vancouver

Mulford KL, Roman RD, Labott JR, Kaji ES, Grove AF, Taunton MJ, et al. An algorithm for automated femoral leg length and offset calculations on pelvis radiographs. HIP International. 2026;36(3):388-397. doi:10.1177/11207000261421918

BibTeX
@article{Mulford2026,
  author = {Mulford, Kellen L and Roman, Ryan D and Labott, Joshua R and Kaji, Elizabeth S and Grove, Austin F and Taunton, Michael J and Wyles, Cody C},
  title = {An algorithm for automated femoral leg length and offset calculations on pelvis radiographs},
  journal = {HIP International},
  year = {2026},
  volume = {36},
  number = {3},
  pages = {388--397},
  doi = {10.1177/11207000261421918}
}
Kostenlos starten →