Multidimensional comparison of robot-assisted/manual THA: a systematic review and meta-analysis using REML-HK and multi-model for key outcomes
HIP International · 2026
DOI: 10.1177/11207000251408301 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift HIP International, 2026. Verfasst von Chengbin Yang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Trauma Centre, First Affiliated Hospital of Kunming Medical University, Kunming, Yunnan, China. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Robotic Surgical Procedures. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 72 Literaturangaben. Gefördert von: Yunnan Revitalization Talent Support Program, Science and Technology Plan Project of Yunnan Province Technology Hall, PhD Research Fund Project of the First Affiliated Hospital of Kunming Medical University.
Abstract (Originalsprache)
Background
Total hip arthroplasty (THA) is a standard treatment for advanced hip disorders; however, conventional manual THA (M-THA) is potentially limited by suboptimal prosthesis positioning, a prolonged learning curve, and an elevated risk of complications. Robot-assisted THA (R-THA), with its enhanced accuracy in prosthesis alignment and intraoperative feedback capabilities, has been proposed to address these shortcomings. Nevertheless, the current literature on the differences in clinical outcomes between R-THA and M-THA remains inconsistent and fragmented, warranting a systematic review and meta-analysis. This systematic review and meta-analysis aimed to evaluate the comparative effectiveness of R-THA versus M-THA regarding surgical accuracy, perioperative outcomes, and complications.
Methods
A comprehensive search was performed by 7 general databases prior to November 2024, and studies were collected if they were involved in the comparison between robot-assisted THA and manual THA in the surgical outcomes, including learning curve, operation time, prosthesis placement accuracy (cup anteversion and inclination), Harris Hip Score (HHS), and complications. The R 4.5.1 software was used to calculate the 95% confidence intervals with standardised mean differences and Cohen's d values for continuous variables, as well as odds ratios for binary variables. The methodological bias and potential heterogeneity sources of included studies were evaluated.
Results
A total of 37 studies were analysed in this study. Compared with M-THA, R-THA showed the better accuracy in prosthesis anteversion (OR 2.67; 95% CI, 1.15–6.19) and inclination angles (OR 2.71; 95% CI, 1.47–4.98), a shorter learning curve inflection point (18.48 vs. 63.53), a lower periprosthetic fracture rate (OR 0.54; 95% CI, 0.38–0.77) and a lower incidence of leg length-discrepancy (LLD) (MD -1.42; 95% CI, -2.19–-0.66), but at the cost of a longer operation time (MD 18.16; 95% CI, 8.81–27.51). Moreover, there was no significant difference between the 2 groups in the other complications and HHS (MD -2.04; 95% CI, -6.84–2.76).
Conclusions
R-THA shortens the learning curve, improves implant positioning accuracy, and reduces LLD, although it is associated with longer operative time, while functional outcomes and complication rates remain largely comparable to M-THA. PROSPERO registration number: CRD42025636461.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Trauma Centre, First Affiliated Hospital of Kunming Medical University, Kunming, Yunnan, China.
- Department of Orthopaedics and Traumatology, Cixi Hospital of Traditional Chinese Medicine, Ningbo, Zhejiang, China.
- Department of Orthopaedics, First Affiliated Hospital of Kunming Medical University, Kunming, Yunnan, China.
ORCID-Profile: Yingxing Xu
Förderung
- Yunnan Revitalization Talent Support Program
- Science and Technology Plan Project of Yunnan Province Technology Hall
- PhD Research Fund Project of the First Affiliated Hospital of Kunming Medical University
- National Natural Science Foundation of China
- Yunnan Province medical discipline reserve talent project
Zitieren
APA
Yang, C., Lao, J., Xia, T., Huang, X., & Xu, Y. (2026). Multidimensional comparison of robot-assisted/manual THA: a systematic review and meta-analysis using REML-HK and multi-model for key outcomes. HIP International. https://doi.org/10.1177/11207000251408301
Vancouver
Yang C, Lao J, Xia T, Huang X, Xu Y. Multidimensional comparison of robot-assisted/manual THA: a systematic review and meta-analysis using REML-HK and multi-model for key outcomes. HIP International. 2026. doi:10.1177/11207000251408301
BibTeX
@article{Yang2026,
author = {Yang, Chengbin and Lao, Jinjin and Xia, Tixiong and Huang, Xiaotao and Xu, Yingxing},
title = {Multidimensional comparison of robot-assisted/manual THA: a systematic review and meta-analysis using REML-HK and multi-model for key outcomes},
journal = {HIP International},
year = {2026},
doi = {10.1177/11207000251408301}
}
EUVIMED