Custom triflange acetabular components in conjunction with dual-mobility liners for extreme acetabular bone loss in revision hip arthroplasty: the first reported case series from South Asia
HIP International · 2026
DOI: 10.1177/11207000251406892 ↗Kurz gefasst
Fachartikel in der Zeitschrift HIP International, 2026. Verfasst von Shahid Noor und 5 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedics, Liaquat National Hospital and Medical College - Orthopaedics, Karachi, Pakistan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Reoperation, Acetabulum, Hip Prosthesis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben.
Themen: Mobilisation
Abstract (Originalsprache)
Background
The global demand for primary total hip arthroplasty (THA) and the corresponding demand for revision THA continue to rise. Revision THA in the face of severe acetabular bone loss is challenging, and the custom triflange acetabular component (CTAC) has emerged as a valuable option for the arthroplasty surgeon. Furthermore, dual mobility liners have been advocated as a promising strategy to reduce the risk of dislocation, a common complication in revision THA.
Methods
This retrospective study of prospectively collected data comprised 15 consecutive patients who underwent revision THA with 3D-printed CTACs and dual mobility liners between January 2020 and March 2023. All patients had either Paprosky type 3B defects or pelvic discontinuity. Functional outcomes were evaluated using the modified Harris Hip Score (mHHS) and pain via the Visual Analogue Scale (VAS). Implant survival and complications are reported.
Results
At a mean follow-up of 40 months, mean mHHS improved from 30.46 to 83.90 ( p < 0.001), and VAS pain scores decreased from 7.0 to 1.9 ( p < 0.001). All patients reported favourable outcomes, and no case was complicated by infection, implant loosening, component failure, or revision. Radiographs showed lateralisation of the centre of rotation by about 1 cm in one patient and Brooker class 1 heterotopic ossification in another. However, all patients demonstrated radiographically stable constructs with good osseointegration at final follow-up. Complications included 2 dislocations and 2 transient sciatic nerve palsies (13.3% each). The dislocations were addressed by closed reduction.
Conclusions
The CTAC is a powerful tool for managing extensive acetabular bone loss in revision THA. Our findings demonstrate promising outcomes with significant functional improvement, pain reduction, and implant stability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Orthopaedics, Liaquat National Hospital and Medical College - Orthopaedics, Karachi, Pakistan.
- Dolphin Suite Consulting Rooms, Forster, New South Wales, Australia.
- Mayo Specialist Centre, Taree, New South Wales, Australia.
ORCID-Profile: Michael C Wyatt, Sumaiya Khan, Usman Mahmood
Zitieren
APA
Noor, S., Ahmed, N., Najjad, K. R., Wyatt, M. C., Khan, S., & Mahmood, U. (2026). Custom triflange acetabular components in conjunction with dual-mobility liners for extreme acetabular bone loss in revision hip arthroplasty: the first reported case series from South Asia. HIP International. https://doi.org/10.1177/11207000251406892
Vancouver
Noor S, Ahmed N, Najjad KR, Wyatt MC, Khan S, Mahmood U. Custom triflange acetabular components in conjunction with dual-mobility liners for extreme acetabular bone loss in revision hip arthroplasty: the first reported case series from South Asia. HIP International. 2026. doi:10.1177/11207000251406892
BibTeX
@article{Noor2026,
author = {Noor, Shahid and Ahmed, Nasir and Najjad, Kazim Rahim and Wyatt, Michael C and Khan, Sumaiya and Mahmood, Usman},
title = {Custom triflange acetabular components in conjunction with dual-mobility liners for extreme acetabular bone loss in revision hip arthroplasty: the first reported case series from South Asia},
journal = {HIP International},
year = {2026},
doi = {10.1177/11207000251406892}
}
EUVIMED