Functional and radiological outcomes and complications of Bernese periacetabular osteotomy through modified Stoppa approach
HIP International · 2025-01 · 35 (1) · 83-91
DOI: 10.1177/11207000241280951 ↗Kurz gefasst
Fachartikel in der Zeitschrift HIP International, online erschienen am 24.10.2024. Verfasst von Deniz Akbulut und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Special Akdamar Hospital, Van, Turkey. Hauptthemen laut MEDLINE: Osteotomy, Acetabulum. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
Background
The Smith-Peterson approach and its modifications provide an extensive exposure and allow osteotomies through a single incision. However, the risk of complications increases when the quadrilateral surface, ischial and pubic osteotomy sites cannot be seen. This study aimed to evaluate the surgical characteristics, complications, and functional and radiological outcomes of patients with acetabular dysplasia who underwent Bernese periacetabular osteotomy (PAO) through modified Stoppa approach and plate-screw fixation.
Methods
The study included 31 patients (41 hips) who had undergone PAO using a modified Stoppa approach. The characteristics of patients and the surgical procedure were described. The lateral centre-edge angle (LCEA) and Tönnis roof angle were evaluated in the radiological outcome evaluation. The modified Harris Hip Score (mHHS) was used to evaluate functional outcome. Furthermore, complications were described.
Results
The mean age of the patients was 20.4 ± 9.0 years. Of the 31 patients, 21 underwent unilateral Bernese PAO and 10 underwent bilateral Bernese PAO. The mean follow-up period was 25.1 ± 8.8 months. Postoperatively, the mean mHHS improved significantly (68.8 ± 9.4 vs. 88.8 ± 10.0, p < 0.001). Postoperatively, the mean LCEA and Tönnis roof angle improved significantly (17.7 ± 6.0 vs. 42.2 ± 4.8, p < 0.001 for LCEA and 18.3 ± 5.5 vs. 8.0 ± 2.2, p < 0.001 for Tönnis roof angle). There was no significant correlation between preoperative to postoperative improvement in LCEA or Tönnis roof angle and improvement and mHHS ( p > 0.005). 5 complications were identified: 1 transient sciatic nerve palsy, 1 external iliac vein injury, 1 infection, and 2 screw irritations of acetabulum.
Conclusions
Performing Bernese PAO through a modified Stoppa approach with plate-screw fixation results in acceptable complication rates, immediate early weight-bearing opportunity, and improved functional and radiological outcomes in patients with acetabular dysplasia.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics and Traumatology, Special Akdamar Hospital, Van, Turkey.
- Department of Orthopaedics and Traumatology, Special Medistanbul Hospital, Istanbul, Turkey.
ORCID-Profile: Deniz Akbulut
Zitieren
APA
Akbulut, D., & Coskun, M. (2025). Functional and radiological outcomes and complications of Bernese periacetabular osteotomy through modified Stoppa approach. HIP International, 35(1), 83-91. https://doi.org/10.1177/11207000241280951
Vancouver
Akbulut D, Coskun M. Functional and radiological outcomes and complications of Bernese periacetabular osteotomy through modified Stoppa approach. HIP International. 2025;35(1):83-91. doi:10.1177/11207000241280951
BibTeX
@article{Akbulut2025,
author = {Akbulut, Deniz and Coskun, Mehmet},
title = {Functional and radiological outcomes and complications of Bernese periacetabular osteotomy through modified Stoppa approach},
journal = {HIP International},
year = {2025},
volume = {35},
number = {1},
pages = {83--91},
doi = {10.1177/11207000241280951}
}
EUVIMED