Vergleichsstudie in der Zeitschrift HIP International, 2024. Verfasst von Mark Curtin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Trauma and Orthopaedic Surgery, University Hospital Limerick, Limerick, Ireland. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Reoperation, Hip Prosthesis, Acetabulum. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Revision hip arthroplasty in the presence of complex acetabular deficiencies is challenging. Cement, allograft, reconstruction rings and porous trabecular metal now provide versatile options for acetabular fixation and restoration of acetabular offset. We compare acetabular impaction bone grafting (AIBG) and trabecular metal (TM) cups at long-term follow-up.

Methods

53 patients who underwent revision hip arthroplasty were retrospectively reviewed from local joint registry data. 36 patients were revised using AIBG and 17 with TM. Median clinical follow-up was 9.57 (2.46–18.72) years and 9.65 (7.22–12.46) years, respectively. 82% of the TM group and 63% of the AIBG group were ⩾ Paprosky 2C. Re-revision was considered failure. Radiographs demonstrating 5 mm of femoral head migration and 5° of acetabular component inclination change were considered loose.

Results

Patients receiving AIBG were younger (68 vs. 74 years) with a longer interval from initial arthroplasty to revision (17 vs. 13 years). Revisions in both groups were indicated most commonly for failed cementing (AIBG 88.9% vs. TM 70.5%). No TM reconstructions underwent re-revision, with only 1 failing at 6.3 years, compared with 9 AIBG re-revisions. When revising for sepsis, 33% of AIBG revisions failed.

Conclusions

AIBG demonstrated high failure rates at long-term follow-up when compared to TM constructs. We recommend the use of AIBG in small cavitary defects only. We strongly advise against its use in the setting of significant bony defects and for prosthetic joint infection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipReoperationHip ProsthesisAcetabulumBone TransplantationProsthesis DesignProsthesis FailureHumansMaleFemaleAgedRetrospective StudiesFollow-Up StudiesMiddle AgedTreatment OutcomeTime FactorsBone CementsAged, 80 and over

Stichwörter der Autor:innen

Acetabular impaction bone grafting (AIBG)Harris Hip Score (HHS)Paprosky gradingacetabulumimplantprosthetic joint infection (PJI)revision arthroplastytotal hip arthroplasty (THA)trabecular metal (TM)

Substanzen

Bone Cements

Autor:innen und Institutionen

  • Department of Trauma and Orthopaedic Surgery, University Hospital Limerick, Limerick, Ireland.
  • The Royal College of Surgeons, Ireland.

ORCID-Profile: Mark Curtin

Zitieren

APA

Curtin, M., Russell, S. P., Mirdad, R. S., Irwin, S. C., Rowan, F. E., Masterson, E. L., & Condon, F. (2024). Long-term outcomes of acetabular impaction grafting with cemented cups and trabecular metal for revision hip arthroplasty: a follow-up study. HIP International. https://doi.org/10.1177/11207000241266939

Vancouver

Curtin M, Russell SP, Mirdad RS, Irwin SC, Rowan FE, Masterson EL, et al. Long-term outcomes of acetabular impaction grafting with cemented cups and trabecular metal for revision hip arthroplasty: a follow-up study. HIP International. 2024. doi:10.1177/11207000241266939

BibTeX
@article{Curtin2024,
  author = {Curtin, Mark and Russell, Shane P and Mirdad, Rayyan S and Irwin, Shane C and Rowan, Fiachra E and Masterson, Eric L and Condon, Finbarr},
  title = {Long-term outcomes of acetabular impaction grafting with cemented cups and trabecular metal for revision hip arthroplasty: a follow-up study},
  journal = {HIP International},
  year = {2024},
  doi = {10.1177/11207000241266939}
}
Kostenlos starten →