Vergleichsstudie in der Zeitschrift HIP International, 2024. Verfasst von David Kugelman und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, NYU Langone, New York, NY, USA. Hauptthemen laut MEDLINE: Hemiarthroplasty, Reoperation, Femoral Neck Fractures, Hip Prosthesis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben.
Abstract (Originalsprache)
Introduction
There has been much debate on use of bipolar or unipolar femoral heads in hemiarthroplasty for the treatment of femoral neck fractures. The outcome of these implants should be studied in the America Joint Replacement Registry (AJRR).
Methods
All primary femoral neck fractures treated with hemiarthroplasty between January 2012 and June 2020 were searched in the AJRR. All cause-revision of unipolar and bipolar hemiarthroplasty and reasons for revision were assessed for these patients until June of 2023.
Results
There were no differences in number and reason for all cause revisions between unipolar and bipolar hemiarthroplasty ( p = 0.41). Bipolar hemiarthroplasty had more revisons at 6 months postoperatively ( p = 0.0281), but unipolar hemiarthroplasty had more revisions between 2 and 3 years ( p = 0.0003), and after 3-years ( p = 0.0085), as analysed with a Cox model. Patients with older age (HR = 0.999; 95% CI, 0.998–0.999; p = 0.0006) and higher Charlson Comorbidity Index (HR = 0.996; 95% CI, 0.992– 0.999; p = 0.0192) had a significant increase in revision risk.
Conclusions
We suggest that surgeons should consider using bipolar prosthesis when performing hemiarthroplasty for femoral neck fracture in patients expected to live >2 years post injury.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, NYU Langone, New York, NY, USA.
Zitieren
APA
Kugelman, D., Robin, J. X., Schaffler, B. C., Davidovitch, R., Egol, K., & Schwarzkopf, R. (2024). Revision rate following unipolar versus bipolar hemiarthroplasty. HIP International. https://doi.org/10.1177/11207000241235394
Vancouver
Kugelman D, Robin JX, Schaffler BC, Davidovitch R, Egol K, Schwarzkopf R. Revision rate following unipolar versus bipolar hemiarthroplasty. HIP International. 2024. doi:10.1177/11207000241235394
BibTeX
@article{Kugelman2024,
author = {Kugelman, David and Robin, Joseph X and Schaffler, Benjamin C and Davidovitch, Roy and Egol, Kenneth and Schwarzkopf, Ran},
title = {Revision rate following unipolar versus bipolar hemiarthroplasty},
journal = {HIP International},
year = {2024},
doi = {10.1177/11207000241235394}
}
EUVIMED