EUVIMEDEUVIMED entdecken
Crossref

Optimal retractor insertion point for nerve safety during total hip arthroplasty: an anatomical study on the femoral and sciatic nerves in relation to hip motion

Masakazu Okamoto iD, Yoshinobu Uchihara iD, Kenichiro Saito, Yusuke Inagaki, Pasuk Mahakkanukrauh, Yasuhito Tanaka

HIP International · 2024

DOI: 10.1177/11207000241227399 ↗

Kurz gefasst

Fachartikel in der Zeitschrift HIP International, 2024. Verfasst von Masakazu Okamoto und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Nara Medical University, Kashihara, Nara, Japan. Hauptthemen laut MEDLINE: Sciatic Nerve, Arthroplasty, Replacement, Hip, Femoral Nerve, Cadaver. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Nerve injury is one of the most serious complications of total hip arthroplasty (THA). It is suspected to be a result from nerve compression or direct injury caused by an acetabular retractor. The anatomical relationship between the acetabular rim and the femoral and sciatic nerves, including hip motion, has not been investigated. This study aimed to identify the optimal position for retractor insertion during THA to prevent nerve damage.

Methods

A total of 28 hip joints from 14 freshly frozen cadavers were used. Using an anterolateral approach, each cadaver was immobilised in the lateral decubitus position and deployed to measure the distance between the nerves and the acetabular rim, while the hip joint was changed to the extension, neutral, and flexion positions.

Results

Three femoral nerves were closest to the anterior margin of the acetabulum at 90° and 120° of extension and farthest away at 30° of flexion. The sciatic nerve was closest to the posterior margin of the acetabulum at 90° and 120° of flexion and farthest away at 30° and 150° of extension compared with the other points.

Conclusions

To prevent nerve damage during THA, we suggest that the retractor be inserted at the points where the nerves are the farthest away, such as at 30° and 150°. The femoral and sciatic nerves vary in their movements depending on the hip position. Therefore, the safe insertion of a retractor is recommended for hip flexion of the femoral nerve and extension of the sciatic nerve. Additionally, it is important to carefully insert the retractor along the acetabular margin without penetrating the joint capsule. Overall, this study provides valuable insights into the anatomical location and movement of the femoral and sciatic nerves in relation to hip motion and can help inform surgical techniques for safer THA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Sciatic NerveArthroplasty, Replacement, HipFemoral NerveCadaverRange of Motion, ArticularHip JointHumansMaleFemaleAgedPeripheral Nerve InjuriesAged, 80 and overMiddle AgedAcetabulum

Stichwörter der Autor:innen

Hip motionnerve injuryoptimisationretractor insertiontotal hip arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Nara Medical University, Kashihara, Nara, Japan.
  • Department of Rehabilitation, Nara Medical University, Kashihara, Nara, Japan.
  • Department of Anatomy Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.
  • Excellence Centre in Osteology Research and Training Centre (ORCT), Chiang Mai University, Chiang Mai, Thailand.

ORCID-Profile: Masakazu Okamoto, Yoshinobu Uchihara

Zitieren

APA

Okamoto, M., Uchihara, Y., Saito, K., Inagaki, Y., Mahakkanukrauh, P., & Tanaka, Y. (2024). Optimal retractor insertion point for nerve safety during total hip arthroplasty: an anatomical study on the femoral and sciatic nerves in relation to hip motion. HIP International. https://doi.org/10.1177/11207000241227399

Vancouver

Okamoto M, Uchihara Y, Saito K, Inagaki Y, Mahakkanukrauh P, Tanaka Y. Optimal retractor insertion point for nerve safety during total hip arthroplasty: an anatomical study on the femoral and sciatic nerves in relation to hip motion. HIP International. 2024. doi:10.1177/11207000241227399

BibTeX
@article{Okamoto2024,
  author = {Okamoto, Masakazu and Uchihara, Yoshinobu and Saito, Kenichiro and Inagaki, Yusuke and Mahakkanukrauh, Pasuk and Tanaka, Yasuhito},
  title = {Optimal retractor insertion point for nerve safety during total hip arthroplasty: an anatomical study on the femoral and sciatic nerves in relation to hip motion},
  journal = {HIP International},
  year = {2024},
  doi = {10.1177/11207000241227399}
}
Kostenlos starten →