EUVIMEDEUVIMED entdecken
Crossref

Quantification and severity grading of femoral vessel compression by adverse reactions to metal debris in metal-on-metal total hip arthroplasty

Yousef Al-Khatib, Ben Tyas, Nicholas S Kalson, Nickil Agni, Priyesh Bhutani, Timothy Petheram, Ian Carluke, Paul Partington

HIP International · 2024

DOI: 10.1177/11207000231190738 ↗

Kurz gefasst

Fachartikel in der Zeitschrift HIP International, 2024. Verfasst von Yousef Al-Khatib und 7 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedics, George Eliot Hospital NHS Trust, Nuneaton, UK. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Metal-on-Metal Joint Prostheses. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Metal-on-metal (MoM) total hip arthroplasty (THA) may cause adverse reactions to metal debris (ARMD). ARMD causing femoral vessel compression with serious complications has been described in case reports, but the rate of compression by ARMD is not known. This study aims to investigate the rate, and quantify the severity, of femoral vessel compression in MoM hips with ARMD lesions.

Methods

Patients under surveillance for MoM THA investigated with MRI were studied. In patients with confirmed ARMD, femoral artery (FA) and vein (FV) diameters were measured at the point of maximal compression and compared to contralateral vessels. The primary outcome measure was presence or absence of compression. Cases were then classified by compression ratios. Secondary outcome measures were rates of deep vein thrombosis, revision surgery and time to ARMD from index procedure.

Results

MRI scans for 436 patients with MoM THA were screened. Of these, 211/436 (48.4%) showed evidence of ARMD. Measurements were obtained on 133/211 (63.0%) patients. The FV was compressed in 102/133 (76.7%) and FA in 58/133 (43.6%), while 31/133 (23.3%) patients had no compression. In FVs, 42 demonstrated mild compression, 39 moderate and 21 severe. In FAs, none were severely compressed, 6 were moderate and 52 showed mild compression. There were 3 DVT cases, 2 in patients with moderate FV compression and 1 in patients without FV compression. Revision rates were highest in patients with severe FV compression (14/21, 66.7%). The mean time for MRI-diagnosed ARMD from index procedure was 8 years and 1 month (range 11 months–14.5 years).

Conclusions

Extra-luminal compression of the femoral vessels was found in >75% of patients with ARMD. Although it is not clear whether revision for femoral vessel compression is required, quantification of FV compression may be useful for surgeons and radiologists considering revision for ARMD.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisMetal-on-Metal Joint ProsthesesHumansMetalsFemurReoperationProsthesis DesignProsthesis FailureRetrospective Studies

Stichwörter der Autor:innen

ALVALARMDmetal-on-metal total hip arthroplastyrevision arthroplastytotal hip arthroplasty

Substanzen

Metals

Autor:innen und Institutionen

  • Orthopaedics, George Eliot Hospital NHS Trust, Nuneaton, UK.
  • Trauma and Orthopaedics, Health Education North East, Newcastle Upon Tyne, UK.
  • Department of Orthopaedics, Northumbria Healthcare NHS Foundation Trust, Newcastle Upon Tyne, UK.
  • Department of Radiology, Northumbria Healthcare NHS Foundation Trust, Newcastle Upon Tyne, UK.

Zitieren

APA

Al-Khatib, Y., Tyas, B., Kalson, N. S., Agni, N., Bhutani, P., Petheram, T., Carluke, I., & Partington, P. (2024). Quantification and severity grading of femoral vessel compression by adverse reactions to metal debris in metal-on-metal total hip arthroplasty. HIP International. https://doi.org/10.1177/11207000231190738

Vancouver

Al-Khatib Y, Tyas B, Kalson NS, Agni N, Bhutani P, Petheram T, et al. Quantification and severity grading of femoral vessel compression by adverse reactions to metal debris in metal-on-metal total hip arthroplasty. HIP International. 2024. doi:10.1177/11207000231190738

BibTeX
@article{AlKhatib2024,
  author = {Al-Khatib, Yousef and Tyas, Ben and Kalson, Nicholas S and Agni, Nickil and Bhutani, Priyesh and Petheram, Timothy and Carluke, Ian and Partington, Paul},
  title = {Quantification and severity grading of femoral vessel compression by adverse reactions to metal debris in metal-on-metal total hip arthroplasty},
  journal = {HIP International},
  year = {2024},
  doi = {10.1177/11207000231190738}
}
Kostenlos starten →