Characterising the safety and efficacy of intraocular lens exchange by surgical indication and IOL implantation sites

Timothy E Yap iD, George Vakros, Nikhil Jain, Elizabeth Yang, Paul Sullivan, Rabia Bourkiza

European Journal of Ophthalmology · 2026-11 · 36 (6) · 1582-1590

DOI: 10.1177/11206721261446009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Ophthalmology, online erschienen am 28.04.2026. Verfasst von Timothy E Yap und 5 weiteren Autor:innen. Beteiligte Einrichtung: Moorfields Eye Hospital NHS Foundation Trust, London, UK. Hauptthemen laut MEDLINE: Visual Acuity, Lens Implantation, Intraocular, Lenses, Intraocular, Device Removal. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To examine the visual outcomes and complication rates for IOL (intraocular lens) exchange, analysed by combination of surgical indication and secondary IOL implantation site.

Design

Retrospective case series of IOL exchange procedures performed between June 1998 and July 2018 from a single tertiary referral centre, London, United Kingdom.

Methods

Consecutive IOL exchange procedures with pre-operative and 6-month post-operative visual acuity and complication data were eligible.

Results

318 eyes from 288 patients were included. Mean best-corrected visual acuity (BCVA) improved from 0.82 ± 0.77 to 0.47 ± 0.60 LogMAR at 6 months ( p < 0.001), in particular following complete IOL dislocation (adjusted p < 0.001), partial IOL dislocation (adjusted p = 0.001), refractive indications (adjusted p = 0.02), and pseudophacodonesis (adjusted p = 0.02). The most performed and the greatest BCVA improvement was found with subsequent anterior chamber IOL implantation (−0.44 ± 0.72 LogMAR, n = 214, 67%). The poorest BCVA at 6 months was following IOL exchange for corneal oedema (1.13 ± 0.81 LogMAR, n = 16, 5%). 26% of cases underwent concurrent pars plana vitrectomy, and 15% underwent anterior vitrectomy, with 8% experiencing post-operative cystoid macular oedema.

Conclusions

IOL exchange is safe and effective, however careful patient selection and pre-operative counselling assisted by such data should determine when surgery should be undertaken.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual AcuityLens Implantation, IntraocularLenses, IntraocularDevice RemovalHumansFemaleAgedMaleRetrospective StudiesMiddle AgedPostoperative ComplicationsReoperationAged, 80 and overAdultFollow-Up StudiesPhacoemulsification

Stichwörter der Autor:innen

IOLsLENS / CATARACTpostoperative anterior segment problemssecondary IOL implantationsurgery with high-risk ocular conditions

Autor:innen und Institutionen

  • Moorfields Eye Hospital NHS Foundation Trust, London, UK.

ORCID-Profile: Timothy E Yap

Zitieren

APA

Yap, T. E., Vakros, G., Jain, N., Yang, E., Sullivan, P., & Bourkiza, R. (2026). Characterising the safety and efficacy of intraocular lens exchange by surgical indication and IOL implantation sites. European Journal of Ophthalmology, 36(6), 1582-1590. https://doi.org/10.1177/11206721261446009

Vancouver

Yap TE, Vakros G, Jain N, Yang E, Sullivan P, Bourkiza R. Characterising the safety and efficacy of intraocular lens exchange by surgical indication and IOL implantation sites. European Journal of Ophthalmology. 2026;36(6):1582-1590. doi:10.1177/11206721261446009

BibTeX
@article{Yap2026,
  author = {Yap, Timothy E and Vakros, George and Jain, Nikhil and Yang, Elizabeth and Sullivan, Paul and Bourkiza, Rabia},
  title = {Characterising the safety and efficacy of intraocular lens exchange by surgical indication and IOL implantation sites},
  journal = {European Journal of Ophthalmology},
  year = {2026},
  volume = {36},
  number = {6},
  pages = {1582--1590},
  doi = {10.1177/11206721261446009}
}
Kostenlos starten →