EUVIMEDEUVIMED entdecken
Crossref

Phaco + iStent implant learning curve in a teaching hospital

Diogo Bernardo Matos iD, Rafael Correia Barão iD, Nuno Pinto Ferreira, Riccardo Peschiera, Afonso Cabrita, Bruno Dias, André Diogo Barata, Luís Abegão Pinto iD

European Journal of Ophthalmology · 2026

DOI: 10.1177/11206721251363047 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Ophthalmology, 2026. Verfasst von Diogo Bernardo Matos und 7 weiteren Autor:innen. Beteiligte Einrichtung: Serviço de Oftalmologia - Unidade Local de Saúde Santa Maria, Centro Hospitalar Universitário Lisboa Norte - Hospital Santa Maria, Lisboa, Portugal. Hauptthemen laut MEDLINE: Learning Curve, Hospitals, Teaching, Glaucoma Drainage Implants, Phacoemulsification. Die Arbeit nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose iStent inject ® W is a minimally invasive surgical device aimed at creating an alternative trabecular drainage of aqueous humour, reducing intraocular pressure (IOP). International reports already support efficacy and safety, but evidence is lacking about the early-stage learning curve for this device.

Setting

This research was conducted in a teaching tertiary hospital in Lisbon, Portugal.

Design

Retrospective study on the first 6 iStent inject ® W implants performed by 6 certified ophthalmic surgeons.

Methods

All procedures were combined with cataract surgery (phaco + iStent inject ® W). Primary outcome was total surgical time. Secondary outcomes were complications and postoperative IOP. Outcome data were collected preoperatively and at postoperative days 1, 7, 30, and 90.

Results

Thirty-six patients were included (58% female). Mean age was 73.28 ± 9.65 years. Mean surgical time of first surgery was 35.16 min (range 20 to 55), with surgical time decreasing by 8.5 min throughout the learning curve. Mean preoperative IOP was 21.81 ± 4.74 mmHg with a mean need of 2 medications. At 1-month, mean IOP was 16.00 ± 3.12 mmHg (−26.64% than baseline) while resorting to less medication (2.00 ± 0.94 to 0.66 ± 0.95; p < 0.01). Trabecular meshwork haemorrhage was the most common intra-operative complication reported, and no surgical complications requiring secondary intervention were recorded. Conclusions iStent inject ® W was perceived as a fast-learning procedure, with a significant safety profile in the first cases. The magnitude of IOP reduction of this combined procedure makes it an interesting approach to the glaucoma patient requiring cataract surgery, performed either by a resident under supervision or a glaucoma consultant.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Learning CurveHospitals, TeachingGlaucoma Drainage ImplantsPhacoemulsificationGlaucomaHumansFemaleIntraocular PressureMaleAgedMiddle AgedAged, 80 and overOperative TimePortugalRetrospective StudiesTrabecular Meshwork

Stichwörter der Autor:innen

GlaucomaMIGSiStent inject Wminimally invasive glaucoma surgeryocular hypertension

Autor:innen und Institutionen

  • Serviço de Oftalmologia - Unidade Local de Saúde Santa Maria, Centro Hospitalar Universitário Lisboa Norte - Hospital Santa Maria, Lisboa, Portugal.
  • Instituto de Saúde Ambiental, Faculdade de Medicina, Universidade de Lisboa - Vision Lab, Centro de Estudos das Ciências da Visão, Lisboa, Portugal.
  • Department of Ophthalmology, ASST Garda - Ospedale di Desenzano del Garda, Desenzano del Garda, Italy.

ORCID-Profile: Diogo Bernardo Matos, Rafael Correia Barão, Luís Abegão Pinto

Zitieren

APA

Bernardo Matos, D., Barão, R. C., Ferreira, N. P., Peschiera, R., Cabrita, A., Dias, B., Barata, A. D., & Abegão Pinto, L. (2026). Phaco + iStent implant learning curve in a teaching hospital. European Journal of Ophthalmology. https://doi.org/10.1177/11206721251363047

Vancouver

Bernardo Matos D, Barão RC, Ferreira NP, Peschiera R, Cabrita A, Dias B, et al. Phaco + iStent implant learning curve in a teaching hospital. European Journal of Ophthalmology. 2026. doi:10.1177/11206721251363047

BibTeX
@article{BernardoMatos2026,
  author = {Bernardo Matos, Diogo and Barão, Rafael Correia and Ferreira, Nuno Pinto and Peschiera, Riccardo and Cabrita, Afonso and Dias, Bruno and Barata, André Diogo and Abegão Pinto, Luís},
  title = {Phaco + iStent implant learning curve in a teaching hospital},
  journal = {European Journal of Ophthalmology},
  year = {2026},
  doi = {10.1177/11206721251363047}
}
Kostenlos starten →