Preliminary Evaluation of the Local Tissue Response, Biocompatibility, and Dural Repair of sFilm-FS, a Novel Bioabsorbable Fibrin Sealant, in a Rabbit Dural Defect Model
International Journal of Toxicology · 19.11.2026
DOI: 10.1177/10915818261505783 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Toxicology, online erschienen am 19.11.2026. Verfasst von Yuval Ramot und 6 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Sealantium Medical Ltd.
Abstract (Originalsprache)
Effective closure of dural defects is an essential requirement in neurosurgical procedures to prevent cerebrospinal fluid leakage and associated complications. This exploratory study evaluated the local tissue response, integration, and dural repair potential of sFilm-FS—a novel, bioabsorbable, polymer-supported fibrin sealant patch—compared with a commercially available reference device in a rabbit dural defect model. Six male New Zealand White rabbits underwent creation of a standardized 8-mm cranial defect and 4-mm dural defect, followed by the implantation of either sFilm-FS or the reference device ( n = 3 /group). Following a 4-week observation period, local and systemic responses were evaluated macroscopically and histopathologically using selected scoring principles of the ISO 10993-6:2026 guidelines. Both devices were well tolerated systemically, with no intraoperative or postoperative evidence of CSF leakage or neurological deficits. Macroscopically, sFilm-FS became transparent following application, facilitating direct visualization of the underlying tissue. Histopathologically, the reference device exhibited dispersed residual material and macrophage infiltration consistent with ongoing phagocytic clearance, without forming a continuous fibrotic bridge at 4 weeks. In contrast, sFilm-FS formed an intact, integral patch with circumferential mature capsule formation, completely bridging the dural defect without inducing an inflammatory reaction or underlying cerebral parenchymal damage. Based on ISO 10993-6 semi-quantitative scoring, the total reactivity grade for sFilm-FS was classified as “no reaction.” These preliminary histological findings suggest that sFilm-FS provides favorable continuous dural tissue repair and excellent local biocompatibility, warranting further comprehensive evaluation.
Förderung
- Sealantium Medical Ltd
Zitieren
APA
Ramot, Y., Nyska, A., Kronfeld, N., Cohen, E., Brambilla, I., Lamb, C., & Laub, O. (2026). Preliminary Evaluation of the Local Tissue Response, Biocompatibility, and Dural Repair of sFilm-FS, a Novel Bioabsorbable Fibrin Sealant, in a Rabbit Dural Defect Model. International Journal of Toxicology. https://doi.org/10.1177/10915818261505783
Vancouver
Ramot Y, Nyska A, Kronfeld N, Cohen E, Brambilla I, Lamb C, et al. Preliminary Evaluation of the Local Tissue Response, Biocompatibility, and Dural Repair of sFilm-FS, a Novel Bioabsorbable Fibrin Sealant, in a Rabbit Dural Defect Model. International Journal of Toxicology. 2026. doi:10.1177/10915818261505783
BibTeX
@article{Ramot2026,
author = {Ramot, Yuval and Nyska, Abraham and Kronfeld, Noam and Cohen, Eran and Brambilla, Ilaria and Lamb, Chris and Laub, Orgad},
title = {Preliminary Evaluation of the Local Tissue Response, Biocompatibility, and Dural Repair of sFilm-FS, a Novel Bioabsorbable Fibrin Sealant, in a Rabbit Dural Defect Model},
journal = {International Journal of Toxicology},
year = {2026},
doi = {10.1177/10915818261505783}
}